Stations and air quality measurement methods registered in IIS-Air Quality Information System
CZLNCMCER
Station : 
1027. Ceradice
Type of station : AMS-SRS
pollutant
method
interval
unit
SO2
sulphur dioxide
UVFL
UV-fluorescence
30 min
ug/m^3
NO
nitrogen monoxide
CHLM
chemiluminescence
30 min
ug/m^3
NO2
nitrogen dioxide
CHLM
chemiluminescence
30 min
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
CHLM
chemiluminescence
30 min
ug/m^3
PM10
PM 10 particulate matter 10
RADIO
radiometry - beta ray absorption
30 min
ug/m^3
WV
wind velocity
OPEL
optoelectronic method
30 min
m/s
WD
wind direction
OPEL
optoelectronic method
30 min
deg
p
atmospheric pressure
APRESS
atmospheric pressure measurement
30 min
hPa
h
relative air humidity (h. of air)
CAP
capacitance sensor
30 min
%
GLRD
global radiation
TDM
temperature difference method
30 min
W/m2
T2m
temperature 2m above terrain
PT100
resistance method
30 min
K
CZLNCMLOU
Station : 
1026. Louny
Type of station : AMS-SRS
pollutant
method
interval
unit
SO2
sulphur dioxide
UVFL
UV-fluorescence
30 min
ug/m^3
NO
nitrogen monoxide
CHLM
chemiluminescence
30 min
ug/m^3
NO2
nitrogen dioxide
CHLM
chemiluminescence
30 min
ug/m^3
CO
carbon monoxide
IRABS
IR corel. absorption spectrometry
30 min
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
CHLM
chemiluminescence
30 min
ug/m^3
PM10
PM 10 particulate matter 10
RADIO
radiometry - beta ray absorption
30 min
ug/m^3
CZLNCMNEP
Station : 
1028. Nepomysl
Type of station : AMS-SRS
pollutant
method
interval
unit
SO2
sulphur dioxide
UVFL
UV-fluorescence
30 min
ug/m^3
NO
nitrogen monoxide
CHLM
chemiluminescence
30 min
ug/m^3
NO2
nitrogen dioxide
CHLM
chemiluminescence
30 min
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
CHLM
chemiluminescence
30 min
ug/m^3
PM10
PM 10 particulate matter 10
RADIO
radiometry - beta ray absorption
30 min
ug/m^3
WV
wind velocity
OPEL
optoelectronic method
30 min
m/s
WD
wind direction
OPEL
optoelectronic method
30 min
deg
p
atmospheric pressure
APRESS
atmospheric pressure measurement
30 min
hPa
h
relative air humidity (h. of air)
CAP
capacitance sensor
30 min
%
GLRD
global radiation
TDM
temperature difference method
30 min
W/m2
T2m
temperature 2m above terrain
PT100
resistance method
30 min
K
CZLNCMSMO
Station : 
590. Smolnice
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
GUAJA
guajacol (modif. Jakobs-Hochheiser) - spectrophotometry
24 h
ug/m^3
SPM
suspended particulate matter
GRV
gravimetry
24 h
ug/m^3
CZLNCMSTR
Station : 
1306. Strojetice
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
GUAJA
guajacol (modif. Jakobs-Hochheiser) - spectrophotometry
24 h
ug/m^3
SPM
suspended particulate matter
GRV
gravimetry
24 h
ug/m^3
CZLNCMVYS
Station : 
1006. Vyskov
Type of station : AMS-SRS
pollutant
method
interval
unit
SO2
sulphur dioxide
UVFL
UV-fluorescence
30 min
ug/m^3
NO
nitrogen monoxide
CHLM
chemiluminescence
30 min
ug/m^3
NO2
nitrogen dioxide
CHLM
chemiluminescence
30 min
ug/m^3
NOx
nitrogen oxides(oxides of nitrogen)
CHLM
chemiluminescence
30 min
ug/m^3
PM10
PM 10 particulate matter 10
RADIO
radiometry - beta ray absorption
30 min
ug/m^3
WV
wind velocity
OPEL
optoelectronic method
30 min
m/s
WD
wind direction
OPEL
optoelectronic method
30 min
deg
p
atmospheric pressure
APRESS
atmospheric pressure measurement
30 min
hPa
h
relative air humidity (h. of air)
CAP
capacitance sensor
30 min
%
GLRD
global radiation
TDM
temperature difference method
30 min
W/m2
T2m
temperature 2m above terrain
PT100
resistance method
30 min
K
CZLNHSLPO
Station : 
632. Louny-Podebradova
Type of station : cont.manu.
pollutant
method
interval
unit
SO2
sulphur dioxide
CLM
coulometry
24 h
ug/m^3
CZLNHSZKN
Station : 
600. Zatec-Obrancu miru
Type of station : cont.manu.
pollutant
method
interval
unit
SO2
sulphur dioxide
CLM
coulometry
24 h
ug/m^3
CZLNOZCER
Station : 
1378. Ceradice
Type of station : HM-aerosol
pollutant
method
interval
unit
SPM
suspended particulate matter
GRV
gravimetry
7 d
ug/m^3
Be
beryllium
AAS
atomic absorption spectrometry
7 d
ng/m^3
V
vanadium
AAS
atomic absorption spectrometry
7 d
ng/m^3
Cr
chromium
AAS
atomic absorption spectrometry
7 d
ng/m^3
Fe
iron
AAS
atomic absorption spectrometry
7 d
ng/m^3
As
arsenic
AAS
atomic absorption spectrometry
7 d
ng/m^3
Cd
cadmium
AAS
atomic absorption spectrometry
7 d
ng/m^3
Pb
lead
AAS
atomic absorption spectrometry
7 d
ng/m^3
CZLNRVHOR
Station : 
1251. Horany
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3
CZLNRVPET
Station : 
1315. Petrohrad
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3
CZLNRVSOB
Station : 
1260. Sobechleby
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3
CZLNRVZAT
Station : 
1264. Zatec
Type of station : manual
pollutant
method
interval
unit
SO2
sulphur dioxide
WGAE
West-Gaeke spectrophotometry
24 h
ug/m^3