Stations and air quality measurement methods registered in IIS-Air Quality Information System


CZLNCMCER

Station : 1027. Ceradice
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZLNCMLOU

Station :  1026. Louny
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
CO carbon monoxide IRABS IR corel. absorption spectrometry 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3

CZLNCMNEP

Station :  1028. Nepomysl
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZLNCMSMO

Station :  590. Smolnice
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZLNCMSTR

Station :  1306. Strojetice
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZLNCMVYS

Station :  1006. Vyskov
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZLNHSLPO

Station :  632. Louny-Podebradova
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide CLM coulometry 24 h ug/m^3

CZLNHSZKN

Station :  600. Zatec-Obrancu miru
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide CLM coulometry 24 h ug/m^3

CZLNOZCER

Station :  1378. Ceradice
Type of station : HM-aerosol
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 7 d ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d ng/m^3
As arsenic AAS atomic absorption spectrometry 7 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d ng/m^3

CZLNRVHOR

Station :  1251. Horany
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3

CZLNRVPET

Station :  1315. Petrohrad
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3

CZLNRVSOB

Station :  1260. Sobechleby
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3

CZLNRVZAT

Station :  1264. Zatec
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3