Stations and air quality measurement methods registered in IIS-Air Quality Information System


CZPUCEHLA

Station : 1285. Hlavecnik
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T temperature (unspecificated) PT100 resistance method 30 min K

CZPUCEKAS

Station :  1284. Kasalicky
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T temperature (unspecificated) PT100 resistance method 30 min K

CZPUCMPRE

Station :  1112. Prelouc
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T temperature (unspecificated) PT100 resistance method 30 min K
GLRD global radiation TDM temperature difference method 30 min W/m2

CZPUCMSEZ

Station :  1346. Sezemice
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3

CZPUHSPAD

Station :  399. Pardubice-DUKLA
Type of station : manual-HM
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Al aluminium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ti titanium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Mn manganese AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ni nickel AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cu copper AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Zn zinc AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d/1 mint ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d/1 mint ng/m^3

CZPUHSPAP

Station :  398. Pardubice-Polabiny
Type of station : manual-HM
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) TLAM trithanolamine spectophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Al aluminium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ti titanium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Mn manganese AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ni nickel AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cu copper AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Zn zinc AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d/1 mint ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d/1 mint ng/m^3

CZPUHSPNC

Station :  400. Pardubice-nabr.CSLA
Type of station : manual-HM
pollutant method interval unit
NH3 ammonia BERTH Berthelot method - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ti titanium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Mn manganese AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ni nickel AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Cu copper AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Zn zinc AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d/1 mint ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d/1 mint ng/m^3

CZPUPUPRO

Station :  1418. Pardubice-Rosice
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
BZN benzene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
TLN toluene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
EBZN ethylbenzene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
OXY o-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
MXY m-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
PXY p-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZPURVBYS

Station :  591. Byst
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3

CZPURVHRO

Station :  580. Hrobice
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3

CZPURVUJE

Station :  666. Ujezd
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3