Stations and air quality measurement methods registered in IIS-Air Quality Information System

in the year: 2001


CZDCCMBHO

Station : 1279. Bukova Hora
Klasifikace: B/R/N
Ústecký
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZDCCMDEC

Station :  1014. Decin
Measuring program: BT+EUROAIRNET
Klasifikace: B/U/R
Ústecký
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
CO carbon monoxide IRABS IR corel. absorption spectrometry 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZDCCMLIP

Station :  1303. Lipnice
Klasifikace: B/R/NA
Ústecký
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZDCCMLOB

Station :  1280. Lobendava
Klasifikace: B/R/NA
Ústecký
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZDCCMSNE

Station :  1013. Sneznik
Measuring program: BT
Klasifikace: B/R/AN
Ústecký
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
RAIN precipitation amount (rain am.) RAIN standard rain gauge 30 min mm
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZDCCMVAL

Station :  1015. Valdek
Measuring program: BT+IRIS
Klasifikace: B/R/AN
Ústecký
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZDCHSDEN

Station :  331. Decin-nemocnice
Klasifikace: B/U/R
Ústecký
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide FUCEL el. fuel cell 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) FUCEL el. fuel cell 30 min ug/m^3

CZDCHSDPS

Station :  576. Decin-OHS
Klasifikace: T/U/RC
Ústecký
Type of station : kont.manu.-HM
pollutant method interval unit
SO2 sulphur dioxide FUCEL el. fuel cell 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3

CZDCHSJIL

Station :  760. Jilove
Ústecký
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide CLM coulometry 30 min ug/m^3

CZDCHSSTR

Station :  1201. Varnsdorf-5.ZS Strel.
Klasifikace: T/U/CN
Ústecký
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide FUCEL el. fuel cell 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) FUCEL el. fuel cell 30 min ug/m^3