Stations and air quality measurement methods registered in IIS-Air Quality Information System

in the year: 2001


CZPUCEKAS

Station : 1284. Kasalicky
Klasifikace: I/R/A
Pardubický
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZPUCMPDU

Station :  1465. Pardubice Dukla
Klasifikace: B/U/R
Pardubický
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZPUCMPRE

Station :  1112. Prelouc
Klasifikace: B/S/R
Pardubický
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
h relative air humidity (h. of air) SKIN animal skin 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZPUCMSEZ

Station :  1346. Sezemice
Klasifikace: B/R/N
Pardubický
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3

CZPUHSPAP

Station :  398. Pardubice-Polabiny
Klasifikace: I/U/RC
Pardubický
Type of station : manual-HM
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) TLAM trithanolamine spectophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Cr chromium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Mn manganese AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Ni nickel AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d/1 mint ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d/1 mint ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d/1 mint ng/m^3

CZPUPUPRO

Station :  1418. Pardubice-Rosice
Klasifikace: B/S/RI
Pardubický
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
BZN benzene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
TLN toluene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
EBZN ethylbenzene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
OXY o-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
MXY m-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
PXY p-xylene GCH-VOC gas chromatography - volatile org. compounds 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
p atmospheric pressure APRESS atmospheric pressure measurement 30 min hPa
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K