Stations and air quality measurement methods registered in IIS-Air Quality Information System

in the year: 2001


CZKACMALB

Station :  100. Albrechtice
Klasifikace: B/R/N
Moravskoslezský
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Station : 1365. Albrechtice-HM
Klasifikace: B/R/N
Moravskoslezský
Type of station : TK-aerosol
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h/3 dint ug/m^3
Na sodium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Mg magnesium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Al aluminium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Si silicon XRF X-ray fluorescence 24 h/6 dint ng/m^3
S sulfur XRF X-ray fluorescence 24 h/6 dint ng/m^3
Cl chlorine XRF X-ray fluorescence 24 h/6 dint ng/m^3
K potassium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Ca calcium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Ti titanium XRF X-ray fluorescence 24 h/6 dint ng/m^3
V vanadium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Cr chromium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Mn manganese XRF X-ray fluorescence 24 h/6 dint ng/m^3
Fe iron XRF X-ray fluorescence 24 h/6 dint ng/m^3
Ni nickel XRF X-ray fluorescence 24 h/6 dint ng/m^3
Cu copper XRF X-ray fluorescence 24 h/6 dint ng/m^3
Zn zinc XRF X-ray fluorescence 24 h/6 dint ng/m^3
As arsenic XRF X-ray fluorescence 24 h/6 dint ng/m^3
Se selenium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Br bromine XRF X-ray fluorescence 24 h/6 dint ng/m^3
Rb rubidium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Sr strontium XRF X-ray fluorescence 24 h/6 dint ng/m^3
Pb lead XRF X-ray fluorescence 24 h/6 dint ng/m^3

CZKACMBOH

Station :  1065. Bohumin
Klasifikace: B/S/RI
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKACMCTE

Station :  1066. Cesky Tesin
Klasifikace: B/U/R
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKACMHAV

Station :  1068. Havirov
Measuring program: EUROAIRNET
Klasifikace: B/U/R
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKACMKAR

Station :  1069. Karvina
Measuring program: EUROAIRNET
Klasifikace: B/U/R
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
CO carbon monoxide IRABS IR corel. absorption spectrometry 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
h relative air humidity (h. of air) CAP capacitance sensor 30 min %
GLRD global radiation TDM temperature difference method 30 min W/m2
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKACMORL

Station :  1070. Orlova
Klasifikace: B/U/R
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKACMVER

Station :  1072. Vernovice
Measuring program: EUROAIRNET
Klasifikace: B/R/AI
Moravskoslezský
Type of station : AMS-SRS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZKAHSBCA

Station :  952. Bohumin-Caslavska
Klasifikace: B/U/R
Moravskoslezský
Type of station : manual-HM
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 14 d ng/m^3
V vanadium AAS atomic absorption spectrometry 14 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Hg mercury AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3

CZKAHSCTE

Station :  863. Cesky Tesin
Klasifikace: B/U/R
Moravskoslezský
Type of station : manual-HM
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 14 d ng/m^3
V vanadium AAS atomic absorption spectrometry 14 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Hg mercury AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3

CZKAHSHMU

Station :  564. Havirov-MU
Klasifikace: T/U/RC
Moravskoslezský
Type of station : manual-HM
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 14 d ng/m^3
V vanadium AAS atomic absorption spectrometry 14 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Hg mercury AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3

CZKAHSKOH

Station :  517. Karvina-OHS
Klasifikace: T/U/R
Moravskoslezský
Type of station : kont.manu.-HM
pollutant method interval unit
NOx nitrogen oxides(oxides of nitrogen) TLAM trithanolamine spectophotometry 24 h ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 14 d ng/m^3
V vanadium AAS atomic absorption spectrometry 14 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Hg mercury AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3
BZN benzene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TLN toluene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
EBZN ethylbenzene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
XYs sum of xylens GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
STYR styrene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
CM chloromethane GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TCL trichlormethane GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
CLB chlorbenzene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
DCLs sum of dichlorbenzenes GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TMBs sum of trimethylbenzenes GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
DCM dichlormethane GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
CCl4 tetrachlormethane, carbontetrachlor GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TCM trichlorethylene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TECE tetrachlorethylene GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
TCE trichlorethane GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
F11 Freon 11 GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
F12 Freon 12 GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
F113 Freon 113 GCH-VOC gas chromatography - volatile org. compounds 24 h/6 dint ug/m^3
PAHs polycyclic aromatic hydreocarbons - HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
BaA benzo(a)anthracene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
BbF benzo(b)fluoranthene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
BaP benzo(a)pyrene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
FLU fluoralithene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
PYR pyrene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
CRY chrysene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
BkF benzo(k)fluoranthene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
I123cdP ideno(1,2,3,-cd) pyrene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
DBahA dibenzo(a,h)anthracene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
BghiPRL benzo(g,h,i) perylene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
PAHs_TEQ toxic equivalent of sum PAHs HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
FEN phenanthrene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3
A anthracene HPLC high pressure liquid chromatography 24 h/6 dint ng/m^3

CZKAHSONE

Station :  515. Orlova-nemocnice
Klasifikace: T/S/R
Moravskoslezský
Type of station : manual
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3
Be beryllium AAS atomic absorption spectrometry 14 d ng/m^3
V vanadium AAS atomic absorption spectrometry 14 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 14 d ng/m^3
Mn manganese AAS atomic absorption spectrometry 14 d ng/m^3
Ni nickel AAS atomic absorption spectrometry 14 d ng/m^3
Cu copper AAS atomic absorption spectrometry 14 d ng/m^3
Zn zinc AAS atomic absorption spectrometry 14 d ng/m^3
As arsenic AAS atomic absorption spectrometry 14 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 14 d ng/m^3
Hg mercury AAS atomic absorption spectrometry 14 d ng/m^3
Pb lead AAS atomic absorption spectrometry 14 d ng/m^3

CZKAOZPUK

Station :  1334. Petrovice u Karvine
Klasifikace: I/S/C
Moravskoslezský
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T10m temperature 10m above terrain PT100 resistance method 30 min K
Station : 1397. Petrovice u Karvine-HM
Klasifikace: I/S/C
Moravskoslezský
Type of station : TK-aerosol
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 7 d ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d ng/m^3
As arsenic AAS atomic absorption spectrometry 7 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d ng/m^3

CZKAOZSUN

Station :  1335. Sunychl
Klasifikace: I/S/A
Moravskoslezský
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T10m temperature 10m above terrain PT100 resistance method 30 min K
Station : 1438. Sunychl-HM
Klasifikace: I/S/A
Moravskoslezský
Type of station : TK-aerosol
pollutant method interval unit
SPM suspended particulate matter GRV gravimetry 7 d ug/m^3
Be beryllium AAS atomic absorption spectrometry 7 d ng/m^3
V vanadium AAS atomic absorption spectrometry 7 d ng/m^3
Cr chromium AAS atomic absorption spectrometry 7 d ng/m^3
Fe iron AAS atomic absorption spectrometry 7 d ng/m^3
As arsenic AAS atomic absorption spectrometry 7 d ng/m^3
Cd cadmium AAS atomic absorption spectrometry 7 d ng/m^3
Pb lead AAS atomic absorption spectrometry 7 d ng/m^3