Stations and air quality measurement methods registered in IIS-Air Quality Information System

in the year: 2002


CZOLCMLIT

Station : 1078. Litovel
Klasifikace: B/R/A
Olomoucký
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZOLCMLUK

Station : 1217. Luka
Klasifikace: B/R/N
Olomoucký
Type of station : manual
pollutant method interval unit
SO2 sulphur dioxide WGAE West-Gaeke spectrophotometry 24 h ug/m^3
NOx nitrogen oxides(oxides of nitrogen) GUAJA guajacol (modif. Jakobs-Hochheiser) - spectrophotometry 24 h ug/m^3
SPM suspended particulate matter GRV gravimetry 24 h ug/m^3

CZOLCMOLO

Station : 1075. Olomouc
Measuring program: EUROAIRNET
Klasifikace: B/U/R
Olomoucký
Type of station : AMS
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
CO carbon monoxide IRABS IR corel. absorption spectrometry 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 RADIO radiometry - beta ray absorption 30 min ug/m^3
WV wind velocity OPEL optoelectronic method 30 min m/s
WD wind direction OPEL optoelectronic method 30 min deg
T2m temperature 2m above terrain PT100 resistance method 30 min K

CZOLHSOSM

Station : 1197. Olomouc-Smeralova
Klasifikace: B/U/R
Olomoucký
Type of station : AMS-HM
pollutant method interval unit
SO2 sulphur dioxide UVFL UV-fluorescence 30 min ug/m^3
NO nitrogen monoxide CHLM chemiluminescence 30 min ug/m^3
NO2 nitrogen dioxide CHLM chemiluminescence 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CHLM chemiluminescence 30 min ug/m^3
PM10 PM 10 particulate matter 10 TEOM tapered element oscillating microbalance (TEOM) 30 min ug/m^3
Cr chromium ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3
Mn manganese ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3
Ni nickel ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3
As arsenic ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3
Cd cadmium ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3
Pb lead ICP-MS inductively coupled plasma - mass spectrometry 14 d ng/m^3

CZOLMOOHT

Station : 1247. Olomouc-hotel
Klasifikace: T/S/RC
Olomoucký
Type of station : cont.manu.
pollutant method interval unit
SO2 sulphur dioxide CLM coulometry 30 min ug/m^3
O3 ozone UVABS UV-absorption 30 min ug/m^3
NOx nitrogen oxides(oxides of nitrogen) CLM coulometry 30 min ug/m^3