Stations with maximum daily 8-hour running average concentrations - health protection


Region: Ustecky

Year: 2002
Pollutant: CO-carbon monoxide
Unit: ug/m^3
Limit value (LV): 10000
Margin of tolerance (MT): 6000
Limit value+Margin of tolerance (LV+MT): 16000

No of stations with exceedence of limit + margin of tolerance (LV+MT): 0
on the whole number of stations: 11
in percent: 0.0%

No of stations with exceedence of limit (LV): 0
in percent: 0.0%

No. Indet number. Name of Station Code District Institution Type os Station Measurement Method Classification pLV pLV+MT Max. concentration
1.1014DecinCZDCCMDECDecinCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/R
-
-
3602.7
2.1005MostCZMOCMMOSMostCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/R
-
-
3068.8
3.1012Usti n.L.-mestoCZULCMUNMUsti nad LabemCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/RC
-
-
2770.3
4.1001ChomutovCZCVCMCHOChomutovCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/R
-
-
2390.6
5.1025Litomerice-MlekojedyCZLTCMLIMLitomericeCzech Hydrometeorological InstituteAMS-SRSIRABSB/S/RA
-
-
2387.5
6.1009VsechlapyCZTPCMVSETepliceCzech Hydrometeorological InstituteAMS-SRSIRABSB/R/AI
-
-
1955.5
7.1026LounyCZLNCMLOULounyCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/R
-
-
1802.3
8.1008TepliceCZTPCMTEPTepliceCzech Hydrometeorological InstituteAMS-SRSIRABSB/U/R
-
-
1721.1
9.1011Usti n.L.-KockovCZULCMUNKUsti nad LabemCzech Hydrometeorological InstituteAMS-SRSIRABSB/S/RN
-
-
1583.6
10.1007KrupkaCZTPCMKRUTepliceCzech Hydrometeorological InstituteAMS-SRSIRABSB/R/N
-
-
1255.4
11.1000MedenecCZCVCMMEDChomutovCzech Hydrometeorological InstituteAMS-SRSIRABSB/R/AN
-
-
861.7