logo ČHMÚ

EPREA, Prelouc

index back

Situation in the year: 2003


Basic data
Code of the measuring programme in the given locality: EPREA
Old ISKO number: 1112
Locality: Prelouc
Type of measuring programme: Automated measuring program
Measuring networks:  
Address
Administrator ČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
Ing. Pavel Lichtenberg     
50311  Hradec Králové
Tel:495436164
Fax:495436175
E-mail: pavel.lichtenberg@chmi.cz
Data supplier ČHMÚ - pob.Hradec Králové
Dvorská 410
Ing. Rostislav Jireš     
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: jires@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of concentration in urban areas
Place description
Stanice je umístěna na travnaté ploše v areálu vodní elektrárny.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 GLRD [global radiation] TDM [temperature difference method] W/m2 Yes Yes 0 30min 19.12.1994 30.06.2003 
1 h [relative air humidity (h. of air)] SKIN [animal skin] % Yes Yes 0 30min 01.01.1999 30.06.2003 
1 h [relative air humidity (h. of air)] SKIN [animal skin] % Yes Yes 0 30min 19.12.1994 31.03.1995 
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 16.03.1994 30.06.2003 
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 16.03.1994 30.06.2003 
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 16.03.1994 30.06.2003 
1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa Yes Yes 0 30min 19.12.1994 30.06.1996 
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 01.01.1996 30.06.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 30min 23.03.1994 30.06.2003 
1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 16.03.1994 31.12.1995 
1 T [temperature (unspecificated)] PT100 [resistance method] K Yes Yes 0 30min 01.01.1996 31.12.1998 
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes Yes 0 30min 01.01.1999 30.06.2003 
1 WD [wind direction] OPEL [optoelectronic method] deg Yes Yes 0 30min 01.01.1995 30.06.2003 
1 WV [wind velocity] OPEL [optoelectronic method] m/s Yes Yes 0 30min 19.12.1994 30.06.2003 
 
List of laboratories
Laboratory number 1ČHMÚ - pob.Hradec Králové

Ing. Lichtenberg Pavel
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: pavel.lichtenberg@chmi.cz


indexback