Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | HSERA | ||||||||
Old ISKO number: | 1111 | ||||||||
Locality: | Serlich | ||||||||
Type of measuring programme: | Automated measuring program | ||||||||
Measuring networks: | EUROAIRNET, IRIS | ||||||||
Address | |||||||||
Administrator |
ČHMÚ - pob. Hradec Králové-AIM Dvorská 410 Ing. Pavel Lichtenberg 50311 Hradec Králové |
Tel:495436164 | |||||||
Fax:495436175 | |||||||||
E-mail: pavel.lichtenberg@chmi.cz | |||||||||
Data supplier |
ČHMÚ - pob.Hradec Králové Dvorská 410 Ing. Rostislav Jireš 50311 Hradec Králové |
Tel: 495436164 | |||||||
Fax: 495436175 | |||||||||
E-mail: jires@chmi.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | Evalution of total level of concentrations beckground | ||||||||
Place description | |||||||||
Stanice je umístěna 150m od Masarykovy boudy. | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | No | 0 | 30min | 01.11.1997 | |
1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | 30min | 01.01.1999 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 30min | 21.12.1994 | |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 30min | 21.12.1994 | |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 30min | 21.12.1994 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | 30min | 01.08.1995 | |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 30min | 01.01.1996 | |
1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | Yes | No | 0 | 30min | 01.01.1999 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 30min | 21.12.1994 | |
1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 30min | 09.02.1995 | 31.12.1995 |
1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | Yes | No | 0 | 30min | 01.11.1997 | 31.12.1998 |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | 30min | 01.01.1999 | |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 30min | 01.11.1997 | 07.11.2001 |
1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 30min | 08.11.2001 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 30min | 01.11.1997 | 07.11.2001 |
1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 30min | 08.11.2001 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | ČHMÚ - pob.Hradec Králové Ing. Lichtenberg Pavel 50311 Hradec Králové | Tel: 495436164 | |||||||
Fax: 495436175 | |||||||||
E-mail: pavel.lichtenberg@chmi.cz |