Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | SBRE4 | ||||||||
Old ISKO number: | 94 | ||||||||
Locality: | Brezka | ||||||||
Type of measuring programme: | Monthly throughfall | ||||||||
Measuring networks: | |||||||||
Address | |||||||||
Administrator |
VÚLHM Ing. V. Fadrhonsová, Ing. Milan Bíba CSc. Jíloviště - Strnady 15604 Praha |
Tel: 257892222 | |||||||
Fax: 257921444 | |||||||||
E-mail: fadrhonsova@vulhm.cz | |||||||||
Data supplier |
VÚLHM Ing. V. Fadrhonsová Jíloviště - Strnady 15604 Praha |
Tel: 257892222 | |||||||
Fax: 257921444 | |||||||||
E-mail: fadrhonsova@vulhm.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | |||||||||
Place description | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | rain [precipitation amount] | RAIN [by weight] | mm | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | cond [conductivity] | PTELDA [conductometry (platinum electrode)] | µS/cm | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | pH [pH] | [pH meter] | - | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Na [sodium ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | K [potassium ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Mg [magnesium ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Ca [calcium ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | NH4 [ammonium particles] | SFA [spectrophotometry] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | NO3 [nitrate - particles] | IC [ion chromatography] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Cl [chlorine ion] | IC [ion chromatography] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | SO4 [sulphate - particles] | IC [ion chromatography] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Al [aluminium ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Fe [iron ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | F [fluorine ion] | IC [ion chromatography] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Zn [zinc ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Mn [manganese ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | ug/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Cu [copper ion] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | mg/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | Co [cobalt ion] | UNKN [unknown method] | mg/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | P-sum [phosphorus sum] | ICP-OES [inductively coupled plasma - optical emission spectroscopy] | mg/l | Yes | Yes | 0 | 1M | 01.01.2002 | |
1 | alk. [alkalinity] | UNKN [unknown method] | mval/l | Yes | Yes | 0 | 1M | 01.01.2002 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | Zkušební laboratoř výzkumného ústavu lesního hospodářství a myslivosti Jíloviště - Strnady 136 15604 Praha 5 | Tel: 257922632 | |||||||
Fax: 257921444 | |||||||||
E-mail: pribyl@vulhm.cz |