Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | ABRAA | ||||||||
Old ISKO number: | 773 | ||||||||
Locality: | Pha4-Branik | ||||||||
Type of measuring programme: | Automated measuring program | ||||||||
Measuring networks: | EUROAIRNET | ||||||||
Address | |||||||||
Administrator |
ČHMÚ - Libuš AIM Generála Šišky 942 Ing. Šilhavý Jan 14000 Praha 4 - Libuš |
Tel:244033467 | |||||||
Fax:241727935 | |||||||||
E-mail: silhavy@chmi.cz | |||||||||
Data supplier |
ČHMÚ - Libuš AIM Generála Šišky 942 Ing. Šilhavý Jan 14000 Praha 4 - Libuš |
Tel: 244033467 | |||||||
Fax: 241727935 | |||||||||
E-mail: silhavy@chmi.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | Usage for operational management and regulation (SRVS) | ||||||||
Place description | |||||||||
Stanice je umístěna na svahu asi 50m od hlavní komunikace. 2.7.2003 - výměna analyzátoru Verewa za FH62 a sondy Kalman za Digitel DPM1 0. 23.7.2004 byla provedena výměna analyzátoru FH62 PM10 se sondou Digitel za MP101 PM10 se sondou Digitel. | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | 1h | 01.09.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 10.03.1992 | 31.12.2003 |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 10.03.1992 | 31.12.2003 |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 10.03.1992 | 31.12.2003 |
1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | Yes | Yes | 0 | 30min | 10.03.1992 | 31.08.1999 |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 20.10.1995 | 31.12.2003 |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 10min | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | 30min | 10.03.1992 | 31.12.2003 |
1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 10.03.1992 | 19.10.1995 |
1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | Yes | Yes | 0 | 30min | 01.01.1996 | 31.08.1999 |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | 1h | 01.09.2004 | |
1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 1h | 01.09.2004 | |
1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 10min | 01.09.2004 | |
1 | WDm [30 min wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 1h | 01.09.2004 | |
1 | WDm [30 min wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 10min | 01.09.2004 | |
1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 1h | 01.09.2004 | |
1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 10min | 01.09.2004 | |
1 | WVm [30min wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 1h | 01.09.2004 | |
1 | WVm [30min wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 10min | 01.09.2004 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 |
ČHMÚ - Libuš AIM Gen.Šišky 942 Ing. Novák Jiří 14000 Praha 4 |
Tel: 244033451 | |||||||
Fax: 241727935 | |||||||||
E-mail: novakj@chmi.cz |