logo ČHMÚ

ASMIA, Pha5-Smichov

Index Back

Situation in the year: 2004


Basic data
Code of the measuring programme in the given locality: ASMIA
Old ISKO number: 1459
Locality: Pha5-Smichov
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET 
Address
Administrator ČHMÚ - Libuš AIM
Generála Šišky 942
Ing. Šilhavý Jan     
14000  Praha 4 - Libuš
Tel:244033467
Fax:241727935
E-mail: silhavy@chmi.cz
Data supplier ČHMÚ - Libuš AIM
Generála Šišky 942
Ing. Šilhavý Jan     
14000  Praha 4 - Libuš
Tel: 244033467
Fax: 241727935
E-mail: silhavy@chmi.cz
Supplementary data
Target of the measurement programme: Usage for operational management and regulation (SRVS)
Place description
Stanice je umístěna nad výjezdem ze Strahovského tunelu na Smíchově. 30.11.2000 došlo k výměně prachoměru. Verewa F703V a sondy PM10 Kalman byly nahrazeny prachoměrem FH 62 I-R se sondami PM10 Anderson. 17.6.2004 došlo k výměně prachoměru FH62 I-R se soundou Anderson za prachom ěr ESA MP101M se sondou PM10 Digitel.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 BZN [benzene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 BZN [benzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 1h 01.07.2004  
1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes No 0 1h 01.01.2004  
1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 EBZN [ethylbenzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 1h 01.07.2004  
1 EBZN [ethylbenzene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes No 0 1h 01.01.2004  
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes Yes 0 30min 17.02.2000 31.12.2003 
1 MPXY [m,p-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 1h 01.07.2004  
1 MXY [m-xylene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 OXY [o-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 1h 01.07.2004  
1 OXY [o-xylene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes No 0 1h 01.01.2004  
1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 30min 08.12.2000 31.12.2003 
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 1h 01.01.2004  
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 PXY [p-xylene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm Yes No 0 1h 01.01.2004  
1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm Yes Yes 0 30min 01.10.2000 31.12.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 1h 01.01.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 10min 01.01.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 30min 20.12.1999 31.12.2003 
1 TLN [toluene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 30min 01.02.2000 31.12.2003 
1 TLN [toluene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 1h 01.07.2004  
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes No 0 1h 01.01.2004  
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes Yes 0 30min 17.02.2000 31.12.2003 
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 10.07.2004  
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 10.07.2004  
1 WD [wind direction] OPEL [optoelectronic method] deg Yes Yes 0 30min 17.02.2000 31.12.2003 
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 10.07.2004  
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 10.07.2004  
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 10.07.2004  
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 10.07.2004  
1 WV [wind velocity] OPEL [optoelectronic method] m/s Yes Yes 0 30min 17.02.2000 31.12.2003 
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 10.07.2004  
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 10.07.2004  

 

List of laboratories
Laboratory number 1 ČHMÚ - Libuš AIM
Gen.Šišky 942
Ing. Novák Jiří     
14000  Praha 4
Tel: 244033451
Fax: 241727935
E-mail: novakj@chmi.cz

Index Back
Valid XHTML 1.0!