Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | JJIHA | ||||||||
Old ISKO number: | 1477 | ||||||||
Locality: | Jihlava | ||||||||
Type of measuring programme: | Automated measuring program | ||||||||
Measuring networks: | EUROAIRNET | ||||||||
Address | |||||||||
Administrator |
ČHMÚ - pob.Brno Kroftova 43 Ing. Zdeněk Elfenbein 61667 Brno |
Tel:541421044 | |||||||
Fax:541421018 | |||||||||
E-mail: elfenbei@chmi.cz | |||||||||
Data supplier |
ČHMÚ - pob.Brno Kroftova 43 RNDr.L.Zábrš 61667 Brno |
Tel: 541421050 | |||||||
Fax: 541421018 | |||||||||
E-mail: zabrs@chmi.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | unresolved | ||||||||
Place description | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | BZN [benzene] | GCH-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 10.06.2004 | |
1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | EBZN [ethylbenzene] | GCH-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 10.06.2004 | |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | No | 0 | 10min | 02.04.2004 | |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | No | 0 | 1h | 02.04.2004 | |
1 | h [relative air humidity (h. of air)] | HAIR [hair hygrometer] | % | Yes | No | 0 | 1h | 02.04.2004 | |
1 | MPXY [m,p-xylene] | GCH-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 10.06.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | OXY [o-xylene] | GCH-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 10.06.2004 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | PM2,5 [fine suspended particles (PM2,5 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM2,5 [fine suspended particles (PM2,5 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | Yes | No | 0 | 10min | 15.10.2004 | |
1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | Yes | No | 0 | 1h | 15.10.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 10min | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | 30min | 03.10.2003 | 31.12.2003 |
1 | TLN [toluene] | GCH-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 10.06.2004 | |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | 1h | 02.04.2004 | |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 10min | 15.10.2004 | |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 1h | 15.10.2004 | |
1 | WDm [30 min wind direction maximum] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 10min | 15.10.2004 | |
1 | WDm [30 min wind direction maximum] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 1h | 15.10.2004 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 10min | 15.10.2004 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 1h | 15.10.2004 | |
1 | WVm [30min wind velocity maximum] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 1h | 15.10.2004 | |
1 | WVm [30min wind velocity maximum] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 10min | 15.10.2004 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 |
ČHMÚ-pob.Brno-AMS Kroftova 43 F.Pařízek 61667 Brno |
Tel: 541421043 | |||||||
Fax: | |||||||||
E-mail: frantisek.parizek@chmi.cz |