Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | LSOUA | ||||||||
Old ISKO number: | 1022 | ||||||||
Locality: | Sous | ||||||||
Type of measuring programme: | Automated measuring program | ||||||||
Measuring networks: | EUROAIRNET, Black triangle | ||||||||
Address | |||||||||
Administrator |
ČHMÚ-pobočka Ústí n/Labem Pošt. přihrádka 2 Ing.Bitter 40011 Ústí n/Labem |
Tel:472706053 | |||||||
Fax:472706024 | |||||||||
E-mail: bitter@chmi.cz | |||||||||
Data supplier |
ČHMÚ-pobočka Ústí n/Labem-AIM Pošt. přihrádka 2 Ing.Bitter Miroslav 40011 Ústí n/Labem |
Tel: 472706053 | |||||||
Fax: 472706024 | |||||||||
E-mail: bitter@chmi.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | Evalution of total level of concentrations beckground | ||||||||
Place description | |||||||||
Vedle domku hrázného VD Souš, ve volné krajině, na rovině v náhorní poloze vedle vodní nádrže. | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | No | 0 | 10min | 01.01.2004 | |
1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | Yes | Yes | 0 | 30min | 24.10.1995 | 31.12.2003 |
1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | 1h | 01.01.2004 | |
1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | Yes | 0 | 30min | 01.01.1997 | 31.12.2003 |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 26.11.1992 | 31.12.2003 |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 26.11.1992 | 31.12.2003 |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 26.11.1992 | 31.12.2003 |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | 30min | 01.06.1993 | 31.12.2003 |
1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | Yes | No | 0 | 1h | 01.01.2004 | |
1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | Yes | Yes | 0 | 30min | 24.10.1995 | 31.12.2003 |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 20.10.1995 | 31.12.2003 |
1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | Yes | No | 0 | 1h | 01.01.2004 | |
1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | Yes | Yes | 0 | 30min | 21.07.1998 | 31.12.2003 |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 10min | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | 30min | 26.11.1992 | 31.12.2003 |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 26.11.1992 | 19.10.1995 |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | 1h | 01.01.2004 | |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | Yes | 0 | 30min | 01.01.1997 | 31.12.2003 |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 1h | 01.01.2004 | |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 10min | 01.01.2004 | |
1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | Yes | 0 | 30min | 24.10.1995 | 31.12.2003 |
1 | WDm [30 min wind direction maximum] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 1h | 01.01.2004 | |
1 | WDm [30 min wind direction maximum] | OPEL [optoelectronic method] | deg | Yes | No | 0 | 10min | 01.01.2004 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 1h | 01.01.2004 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 10min | 01.01.2004 | |
1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | Yes | 0 | 30min | 24.10.1995 | 31.12.2003 |
1 | WVm [30min wind velocity maximum] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 1h | 01.01.2004 | |
1 | WVm [30min wind velocity maximum] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | 10min | 01.01.2004 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 |
pošt. přihrádka 2 Ing. Miroslav Bitter 400 11 Ústí nad Labem |
Tel: 472 706 053 | |||||||
Fax: 472 706 024 | |||||||||
E-mail: bitter@chmi.cz |