logo ČHMÚ

SBERA, Beroun

Index Back

Situation in the year: 2004


Basic data
Code of the measuring programme in the given locality: SBERA
Old ISKO number: 1140
Locality: Beroun
Type of measuring programme: Automated measuring program
Measuring networks:  
Address
Administrator ČHMÚ - Libuš AIM
Generála Šišky 942
Ing. Šilhavý Jan     
14000  Praha 4 - Libuš
Tel:244033467
Fax:241727935
E-mail: silhavy@chmi.cz
Data supplier ČHMÚ - Libuš AIM
Generála Šišky 942
Ing. Šilhavý Jan     
14000  Praha 4 - Libuš
Tel: 244033467
Fax: 241727935
E-mail: silhavy@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of concentration in urban areas
Place description
Stanice je umístěna v bytové zástavbě s velkou hustotou automobilového provozu. 16.6.2004 byla provedena výměna prachoměru Verewa se sondou Kalman za prachoměr MP101 M PM10 se sondou Digitel, prachoměr PM2,5 je se sondou URG.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes No 0 1h 01.01.2004  
1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 30min 01.05.1995 31.12.2003 
1 GLRD [global radiation] TDM [temperature difference method] W/m2 Yes No 0 10min 01.01.2004  
1 GLRD [global radiation] TDM [temperature difference method] W/m2 Yes Yes 0 30min 07.07.1993 31.12.2003 
1 GLRD [global radiation] TDM [temperature difference method] W/m2 Yes No 0 1h 01.01.2004  
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes No 0 1h 01.01.2004  
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes Yes 0 30min 01.10.1998 31.12.2003 
1 h [relative air humidity (h. of air)] SKIN [animal skin] % Yes Yes 0 30min 07.07.1993 30.08.1996 
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 07.07.1993 30.12.2003 
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 07.07.1993 31.12.2003 
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 1h 01.01.2004  
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 07.07.1993 31.12.2003 
1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa Yes No 0 1h 01.01.2004  
1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa Yes Yes 0 30min 07.07.1993 31.12.2003 
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 1h 01.01.2004  
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 20.10.1995 31.12.2003 
1 PM2,5 [fine suspended particles (PM2,5 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 1h 16.06.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 1h 01.01.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 30min 07.07.1993 31.12.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 10min 01.01.2004  
1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 07.07.1993 19.10.1995 
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes No 0 1h 01.01.2004  
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes Yes 0 30min 07.07.1993 31.12.2003 
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 01.01.2004  
1 WD [wind direction] OPEL [optoelectronic method] deg Yes Yes 0 30min 07.07.1993 31.12.2003 
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 01.01.2004  
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 01.01.2004  
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 01.01.2004  
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 01.01.2004  
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 01.01.2004  
1 WV [wind velocity] OPEL [optoelectronic method] m/s Yes Yes 0 30min 07.07.1993 31.12.2003 
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 01.01.2004  
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 01.01.2004  

 

List of laboratories
Laboratory number 1 ČHMÚ - Libuš AIM
Gen.Šišky 942
Ing. Novák Jiří     
14000  Praha 4
Tel: 244033451
Fax: 241727935
E-mail: novakj@chmi.cz

Index Back
Valid XHTML 1.0!