logo ČHMÚ

TTROA, Trinec-Kosmos

Index Back

Situation in the year: 2004


Basic data
Code of the measuring programme in the given locality: TTROA
Old ISKO number: 1188
Locality: Trinec-Kosmos
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET 
Address
Administrator ČHMÚ - pob.Ostrava
K Myslivně 3/2182
Mgr. Libor  Černikovský   
70800  Ostrava - Poruba
Tel:596 900 218
Fax:596 910 284
E-mail: cernikov@chmi.cz
Data supplier
K Myslivně 3/2182
Mgr. Libor  Černikovský   
708 00  Ostrava-Poruba
Tel: 596 900 218
Fax: 596 910 284
E-mail: cernikov@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of concentration in urban areas
Place description
Stanice umístěna na volném prostranství sídlištního centra.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 BZN [benzene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 1h 01.01.2004  
1 EBZN [ethylbenzene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 1h 01.01.2004  
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes No 0 1h 01.01.2004  
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes Yes 0 30min 01.04.1996 31.12.2003 
1 MPXY [m,p-xylene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 1h 01.01.2004  
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 1h 01.01.2004  
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No Yes 0 30min 01.01.1994 31.12.2003 
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 1h 01.01.2004  
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No Yes 0 30min 01.01.1994 31.12.2003 
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 1h 01.01.2004  
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No Yes 0 30min 01.01.1994 31.12.2003 
1 OXY [o-xylene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 1h 01.01.2004  
1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 1h 01.01.2004  
1 O3 [ozone] UVABS [UV-absorption] µg/m3 No Yes 0 30min 01.04.1996 31.12.2003 
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 1h 01.01.2004  
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No Yes 0 30min 22.01.1997 31.12.2003 
1 PM2,5 [fine suspended particles (PM2,5 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 1h 01.01.2004  
1 PM2,5 [fine suspended particles (PM2,5 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 31.07.2003 31.12.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 1h 01.01.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 10min 01.01.2004  
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No Yes 0 30min 01.01.1994 31.12.2003 
1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 01.01.1994 21.01.1997 
1 TLN [toluene] GCH-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 1h 01.01.2004  
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes No 0 1h 01.01.2004  
1 T2m [temperature 2m above terrain] PT100 [resistance method] K Yes Yes 0 30min 01.04.1996 31.12.2003 
1 WD [wind direction] ELMAG [electromagnetic method] deg Yes Yes 0 1h 01.01.2004 15.12.2004 
1 WD [wind direction] ELMAG [electromagnetic method] deg Yes Yes 0 10min 01.01.2004 15.12.2004 
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 16.12.2004  
1 WD [wind direction] ELMAG [electromagnetic method] deg Yes Yes 0 30min 01.01.1994 31.12.2003 
1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 16.12.2004  
1 WDm [30 min wind direction maximum] ELMAG [electromagnetic method] deg Yes Yes 0 1h 01.01.2004 15.12.2004 
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 10min 16.12.2004  
1 WDm [30 min wind direction maximum] ELMAG [electromagnetic method] deg Yes Yes 0 10min 01.01.2004 15.12.2004 
1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg Yes No 0 1h 16.12.2004  
1 WV [wind velocity] ELMAG [electromagnetic method] m/s Yes Yes 0 1h 01.01.2004 15.12.2004 
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 16.12.2004  
1 WV [wind velocity] ELMAG [electromagnetic method] m/s Yes Yes 0 10min 01.01.2004 15.12.2004 
1 WV [wind velocity] ELMAG [electromagnetic method] m/s Yes Yes 0 30min 01.01.1994 31.12.2003 
1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 16.12.2004  
1 WVm [30min wind velocity maximum] ELMAG [electromagnetic method] m/s Yes Yes 0 1h 01.01.2004 15.12.2004 
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 1h 16.12.2004  
1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s Yes No 0 10min 16.12.2004  
1 WVm [30min wind velocity maximum] ELMAG [electromagnetic method] m/s Yes Yes 0 10min 01.01.2004 15.12.2004 

 

List of laboratories
Laboratory number 1
K Myslivně 3/2182
Ing. Martin  Nevrla   
708 00  Ostrava - Poruba
Tel: 596 900 228
Fax: 596 910 284
E-mail: nevrla@chmi.cz

Index Back
Valid XHTML 1.0!