logo ČHMÚ

HSERA, Serlich

Index Back

Situation in the year: 2005


Basic data
Code of the measuring programme in the given locality: HSERA
Old ISKO number: 1111
Locality: Serlich
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET, IRIS 
Address
Administrator ČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
Ing. Rostislav  Jireš   
50311  Hradec Králové
Tel:495436164
Fax:495436175
E-mail: jires@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of total level of concentrations beckground
Place description
Stanice je umístěna 150m od Masarykovy boudy.
Measurement
Lab. = Laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Sup. Component Method Unit A R Par. Interval Date of start Date of end
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 30min 01.11.1997 31.12.2004 
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 10min 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 1h 01.01.2005  
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 30min 01.01.1999 31.12.2004 
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 1h 01.01.2005  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 21.12.1994 31.12.2004 
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 30min 21.12.1994 31.12.2004 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 21.12.1994 31.12.2004 
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 30min 01.08.1995 31.12.2004 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 01.01.1996 31.12.2004 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2005  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No No 0 30min 01.01.2004 31.12.2004 
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2005  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No No 0 30min 01.01.2004 31.12.2004 
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 1h 01.01.2005  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No No 0 30min 01.01.2004 31.12.2004 
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 10min 01.01.2004  
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No No 0 30min 01.01.1999 31.12.2004 
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 1h 01.01.2005  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 30min 21.12.1994 31.12.2004 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 1h 01.01.2005  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 10min 01.01.2004  
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 09.02.1995 31.12.1995 
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 30min 01.11.1997 31.12.1998 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 30min 01.01.1999 31.12.2004 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 1h 01.01.2005  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 01.01.2004  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2005  
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 30min 01.11.1997 07.11.2001 
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No No 0 30min 08.11.2001 31.12.2004 
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2005  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 30min 01.11.1997 07.11.2001 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No No 0 30min 08.11.2001 31.12.2004 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2005  
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 01.01.2004  
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2005  

 

List of laboratories
Laboratory number 1 ČHMÚ - pob.Hradec Králové
Dvorská 410
Ing.  Josef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: josef.antalik@chmi.cz

 

List of data suppliers
Supplier number 1
Dvorská 410
Ing. Jozef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: jozef.antalik@chmi.cz