logo ČHMÚ

SKLMA, Kladno-stred mesta

Index Back

Situation in the year: 2005


Basic data
Code of the measuring programme in the given locality: SKLMA
Old ISKO number: 1454
Locality: Kladno-stred mesta
Type of measuring programme: Automated measuring program
Measuring networks:  
Address
Administrator ČHMÚ - Libuš CLI
Gen.Šišky 942
Ing. Jan  Šilhavý   
14200  Praha 4 - Libuš
Tel:244033467
Fax:241727935
E-mail: silhavy@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of concentration in urban areas
Place description
Stanice je umístěna v panelové zástavbě u parkoviště, asi 50m od stanice je komunikace se slabým provozem. PM10,PM2,5 - sondy Digitel DPM10, DPM2,5. 22.6.2004 došlo k výměně prachoměrů FH621R PM10 a PM2,5 se sondami Digitel za MP101M PM10-Digitel, PM2,5 sonda URG.
Measurement
Lab. = Laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Sup. Component Method Unit A R Par. Interval Date of start Date of end
1 1 BZN [benzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 BZN [benzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 No No 0 30min 21.10.2003 31.12.2003 
1 1 EBZN [ethylbenzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 EBZN [ethylbenzene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 No No 0 30min 13.11.2003 31.12.2003 
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 1h 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 10min 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 30min 01.01.2000 31.12.2003 
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 1h 01.01.2004  
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 30min 24.05.2000 31.12.2003 
1 1 MPXY [m,p-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 No No 0 30min 21.10.2003 31.12.2003 
1 1 MPXY [m,p-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 10.02.1999 31.12.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 30min 10.02.1999 31.12.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 10.02.1999 31.12.2003 
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 OXY [o-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 No No 0 30min 13.11.2003 31.12.2003 
1 1 OXY [o-xylene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 30min 05.03.1999 31.12.2003 
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No Yes 0 1h 01.01.2004  
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 30min 24.05.2000 31.12.2003 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 10.02.1999 31.12.2003 
1 1 PM2,5 [fine suspended particles (PM2,5 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 PM2,5 [fine suspended particles (PM2,5 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 01.03.2003 31.12.2003 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 30min 10.02.1999 31.12.2003 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 10min 01.01.2004  
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 30min 10.02.1999 31.08.1999 
1 1 TLN [toluene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 No No 0 30min 21.10.2003 31.12.2003 
1 1 TLN [toluene] GCH-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 1h 01.01.2004  
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 30min 08.04.1999 31.12.2003 
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 16.07.2004  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 16.07.2004  
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 30min 08.04.1999 31.12.2003 
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 16.07.2004  
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 16.07.2004  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 30min 08.04.1999 31.12.2003 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 16.07.2004  
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 16.07.2004  
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 16.07.2004  
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 16.07.2004  

 

List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
Ing. Jiří  Novák   
14300  Praha 4 - Libuš
Tel: 244033484
Fax: 241727935
E-mail: novakj.chmi.cz

 

List of data suppliers
Supplier number 1
Generála Šišky 942
Ing. Jan  Šilhavý   
14000  Praha 4 - Libuš
Tel: 244033467
Fax: 241727935
E-mail: silhavy@chmi.cz

Index Back
Valid XHTML 1.0!