logo ČHMÚ

BMISA, Mikulov-Sedlec

Index Back

Situation in the year: 2006


Basic data
Code of the measuring programme in the given locality:BMISA
Old ISKO number:1135
Locality: Mikulov-Sedlec
Type of measuring programme: Automated measuring program
Measuring networks:IRIS 
Address
AdministratorČHMÚ - pob.Brno
Kroftova 43
Mgr. Robert  Skeřil   
61667  Brno
Tel:541421046
Fax:541421018
E-mail: robert.skeril@chmi.cz
Supplementary data
Target of the measurement programme:Data for research, models, verification, etc.
Place description
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11BZN [benzene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11BZN [benzene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11EBZN [ethylbenzene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11EBZN [ethylbenzene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoNo0No30min01.10.199431.12.2003 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No1h01.01.2004 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No10min01.01.2004 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min01.10.199431.12.2003 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2004 
11MPXY [m,p-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h17.03.2004 
11MXY [m-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11MXY [m-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No1h01.01.200416.03.2004 
11NH3 [ammonia] CHLM [chemiluminescence]µg/m3NoYes0No1h01.01.2004 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3NoNo0No30min01.10.199431.12.2003 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence]µg/m3NoNo0No30min01.10.199431.12.2003 
11NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3NoNo0No30min01.10.199431.12.2003 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11OXY [o-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11OXY [o-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11O3 [ozone] UVABS [UV-absorption]µg/m3NoNo0No30min06.03.199631.12.2003 
11O3 [ozone] UVABS [UV-absorption]µg/m3YesYes0Yes1h01.01.2004 
11p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoNo0No30min01.10.199431.12.2003 
11p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoYes0No1h01.01.200431.12.2004 
11PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption]µg/m3YesYes0Yes1h01.01.2004 
11PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min21.10.199531.12.2003 
11PXY [p-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No1h01.01.200416.03.2004 
11PXY [p-xylene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2004 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No10min01.02.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No10min01.01.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No1h01.01.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No10min01.01.2004 
11RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge]mmNoYes0No1h01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3NoNo0No30min01.10.199431.12.2003 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2004 
11SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min01.10.199420.10.1995 
11T [temperature (unspecificated)] PT100 [resistance method]KNoNo0No30min01.10.199420.06.2003 
11TLN [toluene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3NoNo0No30min01.04.199831.12.2003 
11TLN [toluene] GCH-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min20.06.200331.12.2003 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No30min01.10.199431.12.2003 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No10min01.01.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No1h01.01.2004 
11WDm [30 min wind direction maximum] OPEL [optoelectronic method]degNoYes0No1h01.01.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No1h01.01.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoNo0No30min01.10.199431.12.2003 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No10min01.01.2004 
11WVm [30min wind velocity maximum] OPEL [optoelectronic method]m/sNoYes0No1h01.01.2004 

 

List of laboratories
Laboratory number 1ČHMÚ-pob.Brno-AMS
Kroftova 43
  Sviták,Pařízek   
61667  Brno
Tel: 541421043
Fax:
E-mail: josef.svitak@chmi.cz

 

List of data suppliers
Supplier number 1
Kroftova 43
Mgr. Robert  Skeřil   
61667  Brno
Tel: 541421046
Fax: 541421018
E-mail: robert.skeril@chmi.cz

IndexBack