logo ČHMÚ

KPRBA, Prebuz

Index Back

Situation in the year: 2006


Basic data
Code of the measuring programme in the given locality:KPRBA
Old ISKO number:1033
Locality: Prebuz
Type of measuring programme: Automated measuring program
Measuring networks:Black triangle, IRIS 
Address
AdministratorČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
Ing. Miroslav  Bitter   
40011  Ústí n/Labem
Tel:472706053
Fax:472706024
E-mail: bitter@chmi.cz
Supplementary data
Target of the measurement programme:Usage for operational management and regulation (SRVS)
Place description
Otevřená poloha na náhorní rovině na okraji louky na SV okraji osady, nejbližší domky cca 80m. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11GLRD [global radiation] TDM [temperature difference method]W/m2NoNo0No30min01.09.200331.12.2003 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No10min01.01.2004 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No1h01.01.2004 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2004 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min01.09.200331.12.2003 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3NoNo0No30min04.04.199331.12.2003 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence]µg/m3NoNo0No30min04.04.199331.12.2003 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3NoNo0No30min04.04.199331.12.2003 
11O3 [ozone] UVABS [UV-absorption]µg/m3YesYes0Yes1h01.01.2004 
11O3 [ozone] UVABS [UV-absorption]µg/m3NoNo0No30min20.04.199431.12.2003 
11p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoNo0No30min01.09.200331.12.2003 
11p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoYes0No1h01.01.2004 
11PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min21.10.199531.12.2003 
11PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption]µg/m3YesYes0No1h01.01.2004 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2004 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No10min01.01.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No10min01.01.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No1h01.01.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No10min01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3NoNo0No30min04.04.199331.12.2003 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2004 
11SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min04.04.199320.10.1995 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min01.09.200331.12.2003 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No1h01.01.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No10min01.01.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No30min01.09.200331.12.2003 
11WDm [30 min wind direction maximum] OPEL [optoelectronic method]degNoYes0No1h01.01.2004 
11WDm [30 min wind direction maximum] OPEL [optoelectronic method]degNoYes0No10min01.01.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No10min01.01.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoNo0No30min01.09.200331.12.2003 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No1h01.01.2004 
11WVm [30min wind velocity maximum] OPEL [optoelectronic method]m/sNoYes0No1h01.01.2004 
11WVm [30min wind velocity maximum] OPEL [optoelectronic method]m/sNoYes0No10min01.01.2004 

 

List of laboratories
Laboratory number 1
pošt. přihrádka 2
Ing. Miroslav  Bitter   
400 11  Ústí nad Labem
Tel: 472 706 053
Fax: 472 706 024
E-mail: bitter@chmi.cz

 

List of data suppliers
Supplier number 1
Pošt. přihrádka 2
Ing. Miroslav  Bitter   
40011  Ústí n/Labem
Tel: 472706053
Fax: 472706024
E-mail: bitter@chmi.cz

IndexBack