AMLYA, Pha5-Mlynarka
Situation in the year: 2007
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | AMLYA | ||||||||||
Old ISKO number: | 775 | ||||||||||
Locality: | Pha5-Mlynarka | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | EUROAIRNET | ||||||||||
Address | |||||||||||
Administrator | ČHMÚ - Libuš CLI Gen.Šišky 942 Ing. Jan Šilhavý 14200 Praha 4 - Libuš | Tel:244033467 | |||||||||
Fax:241727935 | |||||||||||
E-mail: silhavy@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Usage for operational management and regulation (SRVS) | ||||||||||
Place description | |||||||||||
Stanice je umístěna na svahu asi 50m od frekventované komunikace. 30.11.2000 došlo k výměně prachoměru. Verewa F703V a sondy PM10 Kalman byly nahrazeny prachoměrem FH 62 I-R se sondami PM10 Anderson. 9.7.2003 - výměna sondy PM10 Anderson za sondu Digitel DPM10, u PM2,5 je so nda idigitel DPM2,5. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [fine particles PM2,5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 01.01.2004 | 31.07.2008 |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.02.1992 | 31.12.2003 |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 10min | 01.10.2004 | 31.07.2008 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.02.1992 | 31.12.2003 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.02.1992 | 31.12.2003 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.02.1992 | 31.12.2003 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 30min | 30.06.1993 | 31.12.2003 |
1 | 1 | PM2,5 [fine particles PM2,5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 01.03.2003 | 31.12.2003 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 19.10.1995 | 31.12.2003 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 01.02.1992 | 18.10.1995 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 01.02.1992 | 31.08.1999 |
1 | 1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 01.01.1996 | 31.08.1999 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | ČHMÚ-CLI TK Gen.Šišky 942 Ing. Jiří Novák 14300 Praha 4 - Libuš | Tel: 244033484 | |||||||
Fax: 241727935 | |||||||||
E-mail: novakj.chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Generála Šišky 942 Ing. Jan Šilhavý 14000 Praha 4 - Libuš | Tel: 244033467 | |||||||
Fax: 241727935 | |||||||||
E-mail: silhavy@chmi.cz |