BBMLA, Brno-Lany
Situation in the year: 2007
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | BBMLA | ||||||||||
Old ISKO number: | 1638 | ||||||||||
Locality: | Brno-Lany | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | AMS-SRS | ||||||||||
Address | |||||||||||
Administrator | Malinovského nám. 3 Vladimír Halm 601 67 Brno | Tel:542 173 331 | |||||||||
Fax:542 173 396 | |||||||||||
E-mail: halm.vladimir@brno.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||||
Place description | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 10min | 01.01.2007 | |
1 | 1 | [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | PM1 [fine particles PM1] | OPEL [optoelectronic method] | µg/m3 | Yes | No | 0 | No | 1h | 11.12.2008 | |
1 | 1 | PM2,5 [fine particles PM2,5] | OPEL [optoelectronic method] | µg/m3 | Yes | No | 0 | No | 1h | 11.12.2008 | |
1 | 1 | PM10 [particles PM10] | OPEL [optoelectronic method] | µg/m3 | Yes | No | 0 | No | 1h | 11.12.2008 | |
1 | 1 | [wind velocity] | ELMAG [electromagnetic method] | m/s | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [wind velocity] | OPEL [optoelectronic method] | m/s | Yes | No | 0 | No | 10min | 01.01.2007 | |
1 | 1 | [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | No | 10min | 01.01.2007 | |
1 | 1 | [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | No | 1h | 01.01.2007 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 1h | 01.01.2007 | 11.12.2008 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 26.09.2002 | 31.12.2006 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 01.01.2000 | 24.09.2002 |
1 | 1 | WV [wind velocity] | ELMAG [electromagnetic method] | m/s | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | No | 30min | 01.01.2000 | 31.12.2006 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | Holzova 14/750 Radek Jordan 628 00 Brno | Tel: 542 174 558 | |||||||
Fax: 542 174 508 | |||||||||
E-mail: radek.jordan@site.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Kroftova 43 Mgr. Robert Skeřil 61667 Brno | Tel: 541421046 | |||||||
Fax: 541421018 | |||||||||
E-mail: robert.skeril@chmi.cz |