TOFFA, Ostrava-Fifejdy
Situation in the year: 2007
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | TOFFA | ||||||||||
Old ISKO number: | 1061 | ||||||||||
Locality: | Ostrava-Fifejdy | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | EUROAIRNET | ||||||||||
Address | |||||||||||
Administrator | ČHMÚ - pob.Ostrava K Myslivně 3/2182 Mgr. Libor Černikovský 70800 Ostrava - Poruba | Tel:596 900 218 | |||||||||
Fax:596 910 284 | |||||||||||
E-mail: cernikov@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||||
Place description | |||||||||||
Rovinný pozemek na sídlišti Ostrava-Fifejdy. Dobrá otevřená lokalita. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 01.01.2004 | |
1 | 1 | [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [benzene] | GC-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [toluene] | GC-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [ethylbenzene] | GC-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [m,p-xylene] | GC-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [o-xylene] | GC-FID [gas chromatography - flame-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [short-term wind velocity maximum] | OPEL [optoelectronic method] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [short-term wind direction maximum] | OPEL [optoelectronic method] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | No | Yes | 0 | No | 1h | 15.08.2008 | |
1 | 1 | [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 12.03.1992 | 31.12.2003 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 12.03.1992 | 31.12.2003 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 12.03.1992 | 31.12.2003 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 12.03.1992 | 31.12.2003 |
1 | 1 | [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | 31.12.2008 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 30min | 01.09.1993 | 31.12.2003 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 01.07.1993 | 31.12.2003 |
1 | 1 | [fine particles PM1] | OPEL [optoelectronic method] | µg/m3 | No | No | 0 | No | 1h | 16.08.2007 | 03.01.2008 |
1 | 1 | [fine particles PM2,5] | OPEL [optoelectronic method] | µg/m3 | No | No | 0 | No | 1h | 16.08.2007 | 03.01.2008 |
1 | 1 | [particles PM10] | OPEL [optoelectronic method] | µg/m3 | No | No | 1 | No | 1h | 16.08.2007 | 03.01.2008 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 21.10.1995 | 31.12.2003 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 12.03.1992 | 20.10.1995 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 01.06.1996 | 12.09.2002 |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | No | 0 | No | 30min | 13.09.2002 | 31.12.2003 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 01.06.1996 | 12.09.2002 |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | No | 0 | No | 30min | 13.09.2002 | 31.12.2003 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 01.06.1996 | 31.12.2003 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 01.06.1996 | 31.12.2003 |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 01.06.1996 | 31.12.2003 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | K Myslivně 3/2182 Ing. Pavel Smolík 708 00 Ostrava - Poruba | Tel: 596 900 228 | |||||||
Fax: 596 910 284 | |||||||||
E-mail: ooco_ova@chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | K Myslivně 3/2182 Mgr. Blanka Krejčí 708 00 Ostrava-Poruba | Tel: 596 900 239 | |||||||
Fax: 596 910 284 | |||||||||