logo ČHMÚ

ESVRB, Svratouch

Situation in the year: 2007


Basic data
Code of the measuring programme in the given locality:ESVRB
Old ISKO number:15
Locality: Svratouch
Type of measuring programme: Bulk samples
Measuring networks:EMEP,Síť monitoringu kvality srážek ČHMÚ 
Address
AdministratorCHMI
Generála Šišky 942
RNDr. Jana  Kubizňáková  CSc. 
14300  Praha 4 - Libuš
Tel: 244033488
Fax: 241727935
E-mail: kubiznakova@chmi.cz
Supplementary data
Target of the measurement programme:stanovení chemického složení srážek a výpočet atmosférické depozice
Place description
Prof.MS 500m od kraje obce, ve volne zem. obdelavane krajine na kopci Otava
Measurement
Lab. = laboratory, Sup. = data supplier, Par. = parallel measurement
Lab.Dod.ComponentMethodUnit Par.IntervalDate of startDate of end
22Ca [calcium ion]FAAS [flame atomic absorption apectrometry]ug/l01d06.07.198631.12.1995 
22Cd [cadmium]GF-AAS [graphite furnace atomic absorption spectrometry]ug/l07d27.02.1996 
22Cd [cadmium]AAS [atomic absorption spectrometry]ug/l01d12.02.198930.04.1995 
22Cl [chlorine ion]IC [ion chromatography]ug/l01d05.02.198931.12.1995 
22vodivost [conductivity]EC meter [EC meter]µS/cm01d02.01.198831.12.1995 
22Fe [iron]FAAS [flame atomic absorption apectrometry]ug/l07d08.01.1985 
11Iont.Bil. [Ion balance]UNKN [unknown method]%07d08.01.1985 
11Iont.Bil. [Ion balance]UNKN [unknown method]%01d01.10.197731.12.1995 
22K [potassium ion]FAAS [flame atomic absorption apectrometry]ug/l01d01.01.198931.12.1995 
22Mg [magnesium ion]FAAS [flame atomic absorption apectrometry]ug/l01d06.07.198631.12.1995 
22Mn [manganese]GF-AAS [graphite furnace atomic absorption spectrometry]ug/l07d01.10.1996 
22Mn [manganese]AAS [atomic absorption spectrometry]ug/l01d08.02.199430.04.1995 
22Na [sodium ion]FAAS [flame atomic absorption apectrometry]ug/l01d06.07.198631.12.1995 
22NH4 [ammonium ion]IC [ion chromatography]ug/l01d02.11.198631.12.1995 
22Ni [nickel]AAS [atomic absorption spectrometry]ug/l01d12.02.198931.12.1995 
22Ni [nickel]GF-AAS [graphite furnace atomic absorption spectrometry]ug/l07d27.02.1996 
22NO3 [nitrate ion]IC [ion chromatography]ug/l01d01.02.198631.12.1995 
22Pb [lead]AAS [atomic absorption spectrometry]ug/l01d12.02.198931.12.1995 
22Pb [lead]GF-AAS [graphite furnace atomic absorption spectrometry]ug/l07d27.02.1996 
22pH [pH]pH meter [pH meter]-01d01.10.197731.12.1995 
13RAIN [precipitation amount]VOL [volumetric metod]mm07d08.01.1985 
22RAIN [precipitation amount]VOL [volumetric metod]mm01d01.10.197731.12.1995 
22SO4 [sulphate ion]IC [ion chromatography]ug/l01d01.10.197731.12.1995 
11voddif [difference of conductivities]UNKN [unknown method]%07d08.01.1985 
11voddif [difference of conductivities]UNKN [unknown method]%01d01.10.197731.12.1995 
22Zn [zinc]FAAS [flame atomic absorption apectrometry]ug/l07d01.10.1996 
 
List of laboratories
Laboratory number 1neidentifikovano

   
 
Tel:
Fax:
E-mail:
Laboratory number 2CHMI Laboratory n. 1-CLI
Generála Šišky 942
Ing. Jiří  Novák 
14300  Praha 4 - Libuš
Tel: 244033451
Fax:
E-mail: novakj@chmi.cz

 

List of data suppliers
Supplier number 1

     
 
Tel:
Fax:
E-mail:
Supplier number 2
Generála Šišky 942
RNDr. Jana  Kubizňáková  CSc. 
14300  Praha 4 - Libuš
Tel: 244033488
Fax: 241727935
E-mail: kubiznakova@chmi.cz
Supplier number 3
Na Šabatce 17
Ing. Lenka  Stašová   
14306  Praha 4
Tel: 244032354
Fax: 244032357
E-mail: lenka.stasova@chmi.cz