SBERA, Beroun
Situation in the year: 2008
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | SBERA | ||||||||||
Old ISKO number: | 1140 | ||||||||||
Locality: | Beroun | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | |||||||||||
Address | |||||||||||
Administrator | ČHMÚ - Libuš CLI Gen.Šišky 942 Ing. Jan Šilhavý 14200 Praha 4 - Libuš | Tel:244033467 | |||||||||
Fax:241727935 | |||||||||||
E-mail: silhavy@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||||
Place description | |||||||||||
Stanice je umístěna v bytové zástavbě s velkou hustotou automobilového provozu. 16.6.2004 byla provedena výměna prachoměru Verewa se sondou Kalman za prachoměr MP101 M PM10 se sondou Digitel, prachoměr PM2,5 je se sondou URG. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | PM2,5 [fine particles PM2.5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | Yes | 0 | No | 1h | 16.06.2004 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 30min | 01.05.1995 | 31.12.2003 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 20.10.1995 | 31.12.2003 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 07.07.1993 | 19.10.1995 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | h [relative air humidity (h. of air)] | SKIN [animal skin] | % | No | No | 0 | No | 30min | 07.07.1993 | 30.08.1996 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 01.10.1998 | 31.12.2003 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 07.07.1993 | 31.12.2003 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | ČHMÚ-CLI TK Gen.Šišky 942 Ing. Jiří Novák 14300 Praha 4 - Libuš | Tel: 244033484 | |||||||
Fax: 241727935 | |||||||||
E-mail: novakj@chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Generála Šišky 942 Ing. Jan Šilhavý 14000 Praha 4 - Libuš | Tel: 244033467 | |||||||
Fax: 241727935 | |||||||||
E-mail: silhavy@chmi.cz |