UTUSA, Tusimice
Situation in the year: 2009
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | UTUSA | ||||||||||
Old ISKO number: | 1002 | ||||||||||
Locality: | Tusimice | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | AMS-SRS, National air pollution network | ||||||||||
Address | |||||||||||
Administrator | ČHMÚ-pobočka Ústí n/Labem Pošt. přihrádka 2 Ing. Miroslav Bitter 40011 Ústí n/Labem | Tel:472706053 | |||||||||
Fax:472706024 | |||||||||||
E-mail: bitter@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of total level of concentrations beckground | ||||||||||
Place description | |||||||||||
Na pozemku MS - otevřená krajina v rovině mimo zástavbu. V okolí pole, výsypky, doly. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 01.01.2004 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.06.2006 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.06.2006 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.06.2006 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.06.2006 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.06.2006 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.06.2006 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.06.2006 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.06.2006 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 18.01.1992 | 31.12.2003 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 18.01.1992 | 31.12.2003 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 18.01.1992 | 31.12.2003 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 18.01.1992 | 31.12.2003 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 15.04.1994 | 31.12.2003 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 21.10.1995 | 31.12.2003 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 18.01.1992 | 20.10.1995 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 01.01.2004 | 31.05.2006 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 01.01.1995 | 31.12.2003 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 10min | 01.01.2004 | 31.05.2006 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 01.01.2004 | 31.05.2006 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 01.01.1995 | 31.12.2003 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 10min | 01.01.2004 | 31.05.2006 |
1 | 1 | WVm [short-term wind velocity maximum] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 01.01.2004 | 31.05.2006 |
1 | 1 | WVm [short-term wind velocity maximum] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 10min | 01.01.2004 | 31.05.2006 |
1 | 1 | WDm [short-term wind direction maximum] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 01.01.2004 | 31.05.2006 |
1 | 1 | WDm [short-term wind direction maximum] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 10min | 01.01.2004 | 31.05.2006 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 1h | 01.01.2004 | 31.12.2009 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 01.01.1995 | 31.12.2003 |
1 | 1 | h [relative air humidity (h. of air)] | SKIN [animal skin] | % | No | No | 0 | No | 30min | 01.01.1995 | 07.06.1996 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 08.06.1996 | 31.12.2003 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 01.01.1995 | 31.12.2003 |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 01.01.1996 | 31.12.2003 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | pošt. přihrádka 2 Ing. Miroslav Bitter 400 11 Ústí nad Labem | Tel: 472 706 053 | |||||||
Fax: 472 706 024 | |||||||||
E-mail: bitter@chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Pošt. přihrádka 2 Ing. Miroslav Bitter 40011 Ústí n/Labem | Tel: 472706053 | |||||||
Fax: 472706024 | |||||||||
E-mail: bitter@chmi.cz |