Information about air quality in the Czech Republic
Measuring programme table
Updated: 2011-09-02 13:06 CEST
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code: | KPRBA | ||||||||||
Old ISKO number: | 1033 | ||||||||||
Locality: | Prebuz | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | IRIS, National air pollution network | ||||||||||
Administrator | |||||||||||
ČHMÚ-pobočka Ústí n/Labem Pošt. přihrádka 2 40011 Ústí n/Labem |
Tel.: 472706053 | ||||||||||
Fax:.: 472706024 | |||||||||||
E-mail: bitter@chmi.cz | |||||||||||
Target of the measuring programme | |||||||||||
Usage for operational management and regulation (SRVS) | |||||||||||
Cover | |||||||||||
container (air-conditioned) | |||||||||||
Note | |||||||||||
Otevřená poloha na náhorní rovině na okraji louky na SV okraji osady, nejbližší domky cca 80m. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurements | |||||||||||
Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | RAD_A [RAD_A] | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAD_B [RAD_B] | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAD_C [RAD_C] | RAD [dosimeter] | uSV/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-05-01 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-05-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-05-01 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-05-01 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1993-04-04 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1993-04-04 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1993-04-04 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1993-04-04 | 2003-12-31 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1994-04-20 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | 2011-05-11 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1995-10-21 | 2003-12-31 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1993-04-04 | 1995-10-20 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-04-30 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-04-30 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | WVm [short-term wind velocity maximum] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-04-30 |
1 | 1 | WDm [short-term wind direction maximum] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-04-30 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
List of laboratories | |||||||||||
Laboratory number1 |
pošt. přihrádka 2 400 11 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||
Fax:.: 472 706 024 | |||||||||||
E-mail: bitter@chmi.cz | |||||||||||
List of data suppliers | |||||||||||
Supplier number1 | ČHMÚ-pobočka Ústí n/Labem-AIM Pošt. přihrádka 2 40011 Ústí n/Labem |
Tel.: 472706053 | |||||||||
Fax:.: 472706024 | |||||||||||
E-mail: bitter@chmi.cz |