Information about air quality in the Czech Republic
Measuring programme table
Updated: 2011-09-02 13:06 CEST
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code: | PPLAA | ||||||||||
Old ISKO number: | 1322 | ||||||||||
Locality: | Plzen-Slovany | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | |||||||||||
Administrator | |||||||||||
Správa infrastruktury města Plzně Dominikánská 4 301 00 Plzeň |
Tel.: 378035136 | ||||||||||
Fax:.: 378035136 | |||||||||||
E-mail: | |||||||||||
Target of the measuring programme | |||||||||||
Evalution of concentration in urban areas | |||||||||||
Cover | |||||||||||
container (air-conditioned) | |||||||||||
Note | |||||||||||
V kontejneru na volném prostranství v zástavbě s blokovými kotelnami, sousedící s nízkopodlažní zástavbou vilové čtvrti. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurements | |||||||||||
Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | BZN [Benzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | TLN [toluene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | No | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | T10m [temperature 10m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NSVin [number of passing small vehicles - to the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NMVin [number of passing middle-sized vehicles - to the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NBVin [number of passing big vehicles - to the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NEBVin [number of passing extra big vehicles - to the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NSVout [number of passing small vehicles - from the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NMVout [number of passing middle-sized vehicles - from the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NBVout [number of passing big vehicles - from the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | NEBVout [number of passing extra big vehicles - from the centre] | MSZ [microwave sensor] | NV | No | Yes | 0 | No | 1h | 2007-08-14 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | PM2,5 [fine particles PM2.5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 2003-09-01 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | EBZN [ethylbenzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | No | No | 0 | Yes | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | MPXY [m,p-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | No | No | 0 | Yes | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | OXY [o-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | No | No | 0 | Yes | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | WVm [short-term wind velocity maximum] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WDm [short-term wind direction maximum] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 1h | 2004-01-01 | 2009-12-31 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2004-01-01 | 2010-12-09 |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
1 | 1 | T10m [temperature 10m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-02-09 | 2003-12-31 |
List of laboratories | |||||||||||
Laboratory number1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | |||||||||
Fax:.: 377237444 | |||||||||||
E-mail: fory@chmi.cz | |||||||||||
List of data suppliers | |||||||||||
Supplier number1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256643 | |||||||||
Fax:.: 377237444 | |||||||||||
E-mail: hadinger@chmi.cz |