Information about air quality in the Czech Republic
Measuring programme table
Updated: 2011-09-02 13:06 CEST
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code: | SMBOA | ||||||||||
Old ISKO number: | 1437 | ||||||||||
Locality: | Mlada Boleslav | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | National air pollution network | ||||||||||
Administrator | |||||||||||
ČHMÚ - pob. Hradec Králové-AIM Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | ||||||||||
Fax:.: 495 705 001 | |||||||||||
E-mail: martina.cerna@chmi.cz | |||||||||||
Target of the measuring programme | |||||||||||
Evaluation of the effect on the population health, Evalution of concentration in urban areas | |||||||||||
Cover | |||||||||||
container (air-conditioned) | |||||||||||
Note | |||||||||||
Stanice je umístěna ve sportovním areálu blízko sídliště. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurements | |||||||||||
Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2009-01-01 | |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2005-08-01 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
2 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1998-04-16 | 2003-12-31 |
2 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1998-04-16 | 2003-12-31 |
2 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1998-04-16 | 2003-12-31 |
2 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1998-04-16 | 2003-12-31 |
2 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 2003-03-01 | 2003-12-31 |
2 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1998-04-16 | 2003-12-31 |
2 | 1 | WV [wind velocity] | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 1999-02-24 | 2003-12-31 |
2 | 1 | WD [wind direction] | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 1999-02-24 | 2003-12-31 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 1h | 2004-01-01 | 2009-12-31 |
2 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1999-03-17 | 2003-12-31 |
2 | 1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1998-04-16 | 1999-08-31 |
2 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 1999-02-24 | 2003-12-31 |
2 | 1 | RAIN [precipitation amount (rain am.)] | RAIN [standard rain gauge] | mm | No | No | 0 | No | 30min | 1999-04-01 | 2003-12-31 |
2 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1999-02-24 | 2003-12-31 |
List of laboratories | |||||||||||
Laboratory number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | |||||||||
Fax:.: 495 705 001 | |||||||||||
E-mail: martina.cerna@chmi.cz | |||||||||||
Laboratory number2 | ČHMÚ-CLI TK Gen.Šišky 942 14300 Praha 4 - Libuš |
Tel.: 244033484 | |||||||||
Fax:.: 241727935 | |||||||||||
E-mail: novakj@chmi.cz | |||||||||||
List of data suppliers | |||||||||||
Supplier number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | |||||||||
Fax:.: 495 705 001 | |||||||||||
E-mail: martina.cerna@chmi.cz |