Information about air quality in the Czech Republic
Measuring programme table
Updated: 2012-08-30 10:59 CEST
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code: | AREPA | ||||||||||
Old ISKO number: | 771 | ||||||||||
Locality: | Pha1-nam. Republiky | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | EUROAIRNET, National air pollution network | ||||||||||
Administrator | |||||||||||
ČHMÚ - Libuš CLI Gen.Šišky 942 14200 Praha 4 - Libuš |
Tel.: 244033467 | ||||||||||
Fax:.: 241727935 | |||||||||||
E-mail: silhavy@chmi.cz | |||||||||||
Target of the measuring programme | |||||||||||
Usage for operational management and regulation (SRVS) | |||||||||||
Cover | |||||||||||
container (air-conditioned) | |||||||||||
Note | |||||||||||
Measurements | |||||||||||
Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-06-26 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-06-26 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-06-26 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-07-25 | |
1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | WVm [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | WDm [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2007-07-12 | |
1 | 1 | GLRD [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 2007-07-16 | |
1 | 1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2007-06-26 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2007-06-26 | 2008-07-31 |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 10min | 2007-06-26 | 2008-07-31 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | Yes | 1h | 2007-07-01 | 2009-05-31 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-06-26 | 2011-05-31 |
1 | 1 | BZN [Benzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-07-17 | 2012-03-31 |
1 | 1 | TLN [toluene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2007-06-26 | 2012-03-31 |
1 | 1 | EBZN [ethylbenzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | Yes | 1h | 2007-08-01 | 2009-12-31 |
1 | 1 | MPXY [m,p-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | Yes | 1h | 2007-08-01 | 2009-12-31 |
1 | 1 | OXY [o-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | Yes | 1h | 2007-10-01 | 2009-12-31 |
List of laboratories | |||||||||||
Laboratory number1 | ČHMÚ-CLI TK Gen.Šišky 942 14300 Praha 4 - Libuš |
Tel.: 244033484 | |||||||||
Fax:.: 241727935 | |||||||||||
E-mail: novakj@chmi.cz | |||||||||||
List of data suppliers | |||||||||||
Supplier number1 | ČHMÚ - Libuš AIM Generála Šišky 942 14000 Praha 4 - Libuš |
Tel.: 244033467 | |||||||||
Fax:.: 241727935 | |||||||||||
E-mail: silhavy@chmi.cz |