Information about air quality in the Czech Republic
Measuring programme table
Updated: 2015-05-25 16:23 CEST
Basic data | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | ABRAA | |||||||||||
Old ISKO number: | 773 | |||||||||||
Locality: | Praha 4-Branik | |||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||
Measuring networks: | EUROAIRNET, National air pollution network | |||||||||||
Administrator | ||||||||||||
ČHMÚ - Libuš CLI Gen.Šišky 942 143 00 Praha 4 - Libuš |
Tel.: 244033467 | |||||||||||
Fax:.: 241727935 | ||||||||||||
E-mail: silhavy@chmi.cz | ||||||||||||
Target of the measuring programme | ||||||||||||
Usage for operational management and regulation (SRVS) | ||||||||||||
Cover | ||||||||||||
container (air-conditioned) | ||||||||||||
Note | ||||||||||||
Stanice je umístěna na svahu asi 50m od hlavní komunikace. 2.7.2003 - výměna analyzátoru Verewa za FH62 a sondy Kalman za Digitel DPM1 0. 23.7.2004 byla provedena výměna analyzátoru FH62 PM10 se sondou Digitel za MP101 PM10 se sondou Digitel. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. | ||||||||||||
Measurements | ||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | 2011-03-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-03-10 | 2003-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 10min | 2004-10-01 | 2011-03-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-03-10 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-03-10 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-03-10 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1995-10-20 | 2003-12-31 |
1 | 1 | SPM [suspended particulate matter] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1992-03-10 | 1995-10-19 |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2004-10-01 | 2012-12-31 |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2004-10-01 | 2012-12-31 |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-01-01 | 2012-12-31 |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2006-01-01 | 2012-12-31 |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-01-01 | 2012-12-31 |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2007-04-01 | 2012-12-31 |
1 | 1 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1992-03-10 | 1999-08-31 |
1 | 1 | T [temperature (unspecificated)] | - | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-04-01 | 1999-08-31 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | 2012-12-31 |
List of laboratories | ||||||||||||
Laboratory number1 | ČHMÚ-CLI TK Gen.Šišky 942 143 00 Praha 4 - Libuš |
Tel.: 244033451 | ||||||||||
Fax:.: | ||||||||||||
E-mail: novakj@chmi.cz | ||||||||||||
List of data suppliers | ||||||||||||
Supplier number1 | ČHMÚ - Libuš AIM Generála Šišky 942 14000 Praha 4 - Libuš |
Tel.: 244033467 | ||||||||||
Fax:.: 241727935 | ||||||||||||
E-mail: silhavy@chmi.cz |