Information about air quality in the Czech Republic
Measuring programme table
Updated: 2015-05-25 16:23 CEST
Basic data | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | HKRYA | |||||||||||
Old ISKO number: | 1110 | |||||||||||
Locality: | Krkonose-Rychory | |||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||
Measuring networks: | National air pollution network, IRIS, EUROAIRNET | |||||||||||
Administrator | ||||||||||||
ČHMÚ - pob. Hradec Králové-AIM Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 042 | |||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: jan.komarek@chmi.cz | ||||||||||||
Target of the measuring programme | ||||||||||||
Usage for operational management and regulation (SRVS), Evalution of total level of concentrations beckground | ||||||||||||
Cover | ||||||||||||
container (air-conditioned) | ||||||||||||
Note | ||||||||||||
Stanice je umístěna 20m od Rýchorské boudy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | ||||||||||||
Measurements | ||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | RAD_A [RAD_A] | - | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAD_A [RAD_A] | - | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 10min | 2004-01-01 | |
1 | 1 | RAD_B [RAD_B] | - | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAD_B [RAD_B] | - | RAD [dosimeter] | uSv/hod | No | Yes | 0 | No | 10min | 2004-01-01 | |
1 | 1 | RAD_C [RAD_C] | - | RAD [dosimeter] | uSV/hod | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAD_C [RAD_C] | - | RAD [dosimeter] | uSV/hod | No | Yes | 0 | No | 10min | 2004-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2004-11-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2004-11-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2007-01-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2007-01-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2007-01-01 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 2004-12-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1994-05-15 | 2003-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 2004-11-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1994-02-09 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1994-02-09 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1994-02-09 | 2003-12-31 |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1996-01-01 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2006-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1995-12-15 | 2003-12-31 |
1 | 1 | SPM [suspended particulate matter] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1994-03-31 | 1995-12-14 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 1995-06-15 | 2000-11-20 |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | No | 0 | No | 30min | 2000-11-21 | 2003-12-31 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 1995-06-15 | 2000-11-20 |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | No | 0 | No | 30min | 2000-11-21 | 2003-12-31 |
1 | 1 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1995-03-01 | 1996-03-31 |
1 | 1 | T [temperature (unspecificated)] | - | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1998-01-01 | 1998-12-31 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 1997-10-01 | 2003-12-31 |
1 | 1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | No | 0 | No | 30min | 1999-01-01 | 2003-12-31 |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | No | 0 | No | 30min | 1995-03-01 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1999-01-01 | 2003-12-31 |
List of laboratories | ||||||||||||
Laboratory number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | ||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: marketa.bajerova@chmi.cz | ||||||||||||
List of data suppliers | ||||||||||||
Supplier number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | ||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: marketa.bajerova@chmi.cz |