Basic data | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | HTRMA | |||||||||||
Old ISKO number: | 1504 | |||||||||||
Locality: | Trutnov-Mladeznicka | |||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||
Measuring networks: | National air pollution network | |||||||||||
Administrator | ||||||||||||
ČHMÚ - pob. Hradec Králové-AIM Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 042 | |||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: jan.komarek@chmi.cz | ||||||||||||
Target of the measuring programme | ||||||||||||
Usage for operational management and regulation (SRVS), Evalution of concentration in urban areas | ||||||||||||
Cover | ||||||||||||
container (air-conditioned) | ||||||||||||
Note | ||||||||||||
AMS je umístěna v areálu sportovního hřiště ZŠ Trutnov Mládežnická, sídlišt ě Trutnov-Horní Staré Město. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | ||||||||||||
Measurements | ||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-05-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2004-11-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2004-11-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2007-01-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2007-01-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2007-01-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2007-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 2004-11-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | 2013-12-31 |
List of laboratories | ||||||||||||
Laboratory number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | ||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: marketa.bajerova@chmi.cz | ||||||||||||
List of data suppliers | ||||||||||||
Supplier number1 | ČHMÚ - pob.Hradec Králové Dvorská 410 50311 Hradec Králové |
Tel.: 495 705 040 | ||||||||||
Fax:.: 495 705 001 | ||||||||||||
E-mail: marketa.bajerova@chmi.cz |