Information about air quality in the Czech Republic
Measuring programme table
Updated: 2015-05-25 16:23 CEST
Basic data | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | PPLLA | |||||||||||
Old ISKO number: | 1324 | |||||||||||
Locality: | Plzen-Lochotin | |||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||
Measuring networks: | ||||||||||||
Administrator | ||||||||||||
Správa infrastruktury města Plzně Dominikánská 4 301 00 Plzeň |
Tel.: 378035136 | |||||||||||
Fax:.: 378035136 | ||||||||||||
E-mail: | ||||||||||||
Target of the measuring programme | ||||||||||||
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS) | ||||||||||||
Cover | ||||||||||||
container (air-conditioned) | ||||||||||||
Note | ||||||||||||
V kontejneru na volném prostranství mezi bloky zástavby sídlištního typu. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. | ||||||||||||
Measurements | ||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | No | 10min | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | PM1 [fine particles PM1] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | No | 1h | 2010-03-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | No | 1h | 2010-03-01 | |
1 | 1 | PM10 [particles PM10] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | No | 1h | 2010-03-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 2006-11-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 2006-11-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 2006-11-16 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | T10m [temperature 10m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 1h | 2004-01-01 | 2010-02-28 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 10min | 2004-01-01 | 2006-11-16 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | No | 10min | 2004-01-01 | 2006-11-16 |
1 | 1 | WVm [short-term wind velocity maximum] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | No | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | T10m [temperature 10m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-01-05 | 2003-12-31 |
List of laboratories | ||||||||||||
Laboratory number1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | ||||||||||
Fax:.: 377237444 | ||||||||||||
E-mail: fory@chmi.cz | ||||||||||||
List of data suppliers | ||||||||||||
Supplier number1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256643 | ||||||||||
Fax:.: 377237444 | ||||||||||||
E-mail: hadinger@chmi.cz |