Information about air quality in the Czech Republic
Measuring programme table
Updated: 2017-04-10 14:16 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | PPLLA | ||||||||||||||||
Old ISKO number: | 1324 | ||||||||||||||||
Locality: | Plzen-Lochotin | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | |||||||||||||||||
Administrator | |||||||||||||||||
Správa infrastruktury města Plzně Dominikánská 4 301 00 Plzeň |
Tel.: 378035136 | ||||||||||||||||
Fax:.: 378035136 | |||||||||||||||||
E-mail: | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS) | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
V kontejneru na volném prostranství mezi bloky zástavby sídlištního typu. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | |
1 | 1 | PM1 [fine particles PM1] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2010-03-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2010-03-01 | |
1 | 1 | PM10 [particles PM10] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2010-03-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-11-16 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-11-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-11-16 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-11-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-11-16 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-11-05 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-11-16 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-11-05 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | T10m [temperature 10m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-02-28 |
1 | 1 | PM10 [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2006-11-16 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2006-11-16 |
1 | 1 | WVm [short-term wind velocity maximum] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-11-16 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
1 | 1 | T10m [temperature 10m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1996-01-05 | 2003-12-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | |||||||||||||||
Fax:.: 377237444 | |||||||||||||||||
E-mail: fory@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256643 | |||||||||||||||
Fax:.: 377237444 | |||||||||||||||||
E-mail: hadinger@chmi.cz |