Information about air quality in the Czech Republic
Measuring programme table
Updated: 2017-04-10 14:16 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | ZOTMA | ||||||||||||||||
Old ISKO number: | 1961 | ||||||||||||||||
Locality: | Otrokovice - mesto | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | |||||||||||||||||
Administrator | |||||||||||||||||
ENVItech Bohemia s.r.o. Ovocná 1021/34 161 00 Praha 6 |
Tel.: 602 230 160 | ||||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: adamec@envitech.eu | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evaluation of the effect on the population health | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | PM1 [fine particles PM1] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | PM10 [particles PM10] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 10min | 2014-01-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 10min | 2014-01-01 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | N | N | N | N | N | N | 1h | 2014-01-01 | |
List of laboratories | |||||||||||||||||
Laboratory number 1 | ENVItech Bohemia s.r.o. Ovocná 1021/34 161 00 Praha 6 |
Tel.: 602 230 160 | |||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: adamec@envitech.eu | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 | ENVItech Bohemia s.r.o. Ovocná 1021/34 161 00 Praha 6 |
Tel.: 602 230 160 | |||||||||||||||
Fax:.: | |||||||||||||||||
E-mail: adamec@envitech.eu |