Information about air quality in the Czech Republic
Measuring programme table
Updated: 2020-04-30 12:14 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | PKLSA | ||||||||||||||||
Old ISKO number: | 808 | ||||||||||||||||
Locality: | Klatovy soud | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | |||||||||||||||||
Administrator | |||||||||||||||||
ZÚ se sídlem v Ústí n.Labem Pasteurova 9 400 01 Ústí n/L |
Tel.: 477 751 542 | ||||||||||||||||
E-mail: pavel.knedlik@zuusti.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evalution of concentration in urban areas | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
15m od budovy soudu v parku, blízko středu města. Od 1.4.1994 - 30m od budovy soudu v parku na otevřené ploše, v blízkosti středu města. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | PM1 [fine particles PM1] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2016-01-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2016-01-01 | |
1 | 1 | PM10 [particles PM10] | - | OPEL [optoelectronic method] | µg/m3 | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2016-01-01 | |
2 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
2 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
1 | 2 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
1 | 2 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
1 | 2 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m2 | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
2 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
1 | 2 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2009-12-31 |
1 | 2 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2015-08-31 |
1 | 2 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2015-08-31 |
1 | 2 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2015-08-31 |
1 | 2 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2015-08-31 |
1 | 2 | PM10 [particles PM10] | - | TEOM [tapered element oscillating microbalance (TEOM)] | µg/m3 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 2015-08-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 | ZÚ se sídlem v Usti n/L-ZL Plzen 17. listopadu 1 301 00 Plzeň |
Tel.: 371 408 611 | |||||||||||||||
E-mail: jarmila.sladka@zuusti.cz | |||||||||||||||||
Laboratory number 2 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256641 | |||||||||||||||
E-mail: tomas.fory@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 | ČHMÚ - pob. Plzeň Mozartova 41 323 00 Plzeň |
Tel.: 377256643 | |||||||||||||||
E-mail: jan.hadinger@chmi.cz | |||||||||||||||||
Supplier number 2 | ZU se sidlem v Usti n/L-ZL Plzen 17. listopadu 1 301 00 Plzeň |
Tel.: 371 408 611 | |||||||||||||||
E-mail: jarmila.sladka@zuusti.cz |