Information about air quality in the Czech Republic
Measuring programme table
Updated: 2022-11-15 08:08 CET
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | URVHA | ||||||||||||||||
Old ISKO number: | 1317 | ||||||||||||||||
Locality: | Rudolice v Horach | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | AMS-SRS, National air pollution monitoring network , EUROAIRNET | ||||||||||||||||
Administrator | |||||||||||||||||
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2 40011 Ústí n/Labem |
Tel.: 472 706 053 | ||||||||||||||||
E-mail: petr.goll@chmi.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Usage for operational management and regulation (SRVS), Evaluation of the highest air pollutant concentration in a given area | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Náhorní rovina, otevřená krajina, mimo obydlenou obec, travnatý povrch. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 1h | 2004-01-01 | |
1 | 1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2004-01-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-07-01 | |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-07-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-07-01 | |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-07-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-07-01 | |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-07-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2006-07-01 | |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2006-07-01 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-01-01 | |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 2003-12-31 |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 10min | 2004-01-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 2003-12-31 |
1 | 1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 2003-12-31 |
1 | 1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
1 | 1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 2003-12-31 |
1 | 1 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 2003-12-31 |
1 | 1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-20 | 2003-12-31 |
1 | 1 | SPM [suspended particulate matter] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-10-06 | 1995-10-19 |
1 | 1 | BZN [Benzene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2013-12-31 |
1 | 1 | BZN [Benzene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | TLN [toluene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | A | N | N | N | N | N | 1h | 2004-01-01 | 2013-07-31 |
1 | 1 | TLN [toluene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | EBZN [ethylbenzene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2013-07-31 |
1 | 1 | EBZN [ethylbenzene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | OXY [o-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2013-07-31 |
1 | 1 | OXY [o-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | MXY [m-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2013-07-31 |
1 | 1 | MXY [m-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | PXY [p-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2013-07-31 |
1 | 1 | PXY [p-xylene] | - | GC-FID [gas chromatography - flame-ionization detection] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 2002-01-01 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-06-30 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 30min | 1996-05-01 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 10min | 2004-10-01 | 2006-06-30 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-06-30 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 30min | 1996-05-01 | 2003-12-31 |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 10min | 2004-10-01 | 2006-06-30 |
1 | 1 | WVm [short-term wind velocity maximum] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-06-30 |
1 | 1 | WVm [short-term wind velocity maximum] | - | OPEL [optoelectronic method] | m/s | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2006-06-30 |
1 | 1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2006-06-30 |
1 | 1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2006-06-30 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | N | N | N | N | N | N | 30min | 1997-03-01 | 2003-12-31 |
1 | 1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2008-12-31 |
1 | 1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | No | 0 | N | N | N | N | N | N | 30min | 1999-01-01 | 2003-12-31 |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | No | No | 0 | N | N | N | N | N | N | 30min | 1997-03-01 | 2003-12-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1997-03-04 | 2003-12-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 |
CHMI-Usti n/L AIM
pošt. přihrádka 2 400 11 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||||||||
E-mail: petr.goll@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 |
ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2 40011 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||||||||
E-mail: petr.goll@chmi.cz |