Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | SKLSA | ||||||||||||||||
Old ISKO number: | 1455 | ||||||||||||||||
Locality: | Kladno-Svermov | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | National air pollution monitoring network | ||||||||||||||||
Administrator | |||||||||||||||||
ČHMÚ - Libuš CLI
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | ||||||||||||||||
E-mail: stepan.rychlik@chmi.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Usage for operational management and regulation (SRVS), Evaluation of the effect on the population health | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Stanice je umístěna na náměstí, poblíž nízkopodlažní bytové zástavby s četnými lokálními topeništi. V blízkosti stanice parkují automobily. Hlavní komunikace je vzdálena asi 80m. 2.7.2003 výměna analyzátoru PM10 Verewa za FH62, sonda Kalmán vzměněna za D igitel DPM10. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 1h | 2004-01-01 | |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 10min | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 1h | 2004-01-01 | |
1 | 1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 1h | 2004-01-01 | |
1 | 1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | A | A | A | A | R | A | 1h | 2004-01-01 | |
1 | 1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | Yes | 0 | A | N | A | A | A | A | 1h | 2004-01-01 | |
1 | 1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg/m³ | Yes | Yes | 0 | A | N | A | N | R | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 2003-12-31 |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2019-06-28 | 2020-01-31 |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2019-06-28 | 2020-01-31 |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2019-06-28 | 2020-01-31 |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2019-06-28 | 2020-01-31 |
1 | 1 | T [temperature (unspecificated)] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1999-02-10 | 1999-08-31 |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
1 | 1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2019-06-28 | 2020-01-31 |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2019-06-28 | 2020-01-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 |
ČHMÚ-CLI TK
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | |||||||||||||||
E-mail: stepan.rychlik@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 |
ČHMÚ - Libuš AIM
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033467 | |||||||||||||||
E-mail: jan.silhavy@chmi.cz |