Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-06-10 08:42 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | MPSTA | ||||||||||||||||
Old ISKO number: | 1133 | ||||||||||||||||
Locality: | Prostejov | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | National air pollution monitoring network , EUROAIRNET | ||||||||||||||||
Administrator | |||||||||||||||||
ČHMÚ - pob.Ostrava
K Myslivně 3/2182 70800 Ostrava - Poruba |
Tel.: 596 900 218 | ||||||||||||||||
E-mail: blanka.krejci@chmi.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS) | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Střed města - městský park. Stanice byla od 1.1.1994 do 31.12.2003 ve správě pobočky ČHMÚ Brno. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | Yes | 0 | Y | N | A | A | A | A | 1h | 2004-01-01 | |
L1 | D1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | No | 0 | Y | N | N | N | N | N | 1h | 2004-01-01 | 2008-08-12 |
L1 | D1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-01-01 | 2003-12-31 |
L1 | D1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | No | 0 | Y | N | N | N | N | N | 10min | 2004-01-01 | 2008-08-12 |
L1 | D1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
L1 | D1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-01-01 | 2003-12-31 |
L1 | D1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
L1 | D1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-01-01 | 2003-12-31 |
L1 | D1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
L1 | D1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-01-01 | 2003-12-31 |
L1 | D1 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-06-17 | 2003-12-31 |
L1 | D1 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | Yes | Yes | 0 | Y | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
L1 | D1 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1994-06-17 | 2003-12-31 |
L1 | D1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | No | 0 | N | N | N | N | N | N | 30min | 1995-10-20 | 2003-12-31 |
L1 | D1 | SPM [suspended particulate matter] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1994-01-01 | 1995-10-19 |
L1 | D1 | WV [wind velocity] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2004-09-21 |
L1 | D1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-09-22 | 2015-06-09 |
L1 | D1 | WV [wind velocity] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 30min | 1995-11-12 | 2003-12-31 |
L1 | D1 | WV [wind velocity] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2004-09-21 |
L1 | D1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 10min | 2004-09-22 | 2015-06-09 |
L1 | D1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2004-09-21 |
L1 | D1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-09-22 | 2015-06-09 |
L1 | D1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 30min | 1995-11-12 | 2003-12-31 |
L1 | D1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2004-09-21 |
L1 | D1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 10min | 2004-09-22 | 2015-06-09 |
L1 | D1 | WVm [short-term wind velocity maximum] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2004-09-21 |
L1 | D1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 1h | 2007-01-01 | 2015-06-09 |
L1 | D1 | WVm [short-term wind velocity maximum] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2004-09-21 |
L1 | D1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | N | N | N | N | N | N | 10min | 2008-01-01 | 2015-06-09 |
L1 | D1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2004-09-21 |
L1 | D1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 1h | 2007-01-01 | 2015-06-09 |
L1 | D1 | WDm [short-term wind direction maximum] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2004-09-21 |
L1 | D1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | N | N | N | N | N | N | 10min | 2008-01-01 | 2015-06-09 |
L1 | D1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2013-12-31 |
L1 | D1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | No | 0 | N | N | N | N | N | N | 30min | 1996-11-12 | 2003-12-31 |
L1 | D1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2012-12-31 |
L1 | D1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | No | No | 0 | N | N | N | N | N | N | 30min | 1996-11-12 | 2003-12-31 |
L1 | D1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | No | Yes | 0 | N | N | N | N | N | N | 10min | 2004-01-01 | 2012-12-31 |
L1 | D1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2015-06-09 |
L1 | D1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1996-11-12 | 2003-12-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 (L1) |
CHMI-brand Ostrava AIM
K Myslivně 3/2182 708 00 Ostrava - Poruba |
Tel.: 596 900 228 | |||||||||||||||
E-mail: ooco_ova@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 (D1) |
CHMI-brand Ostrava AIM
K Myslivně 3/2182 708 00 Ostrava-Poruba |
Tel.: 596 900 239 | |||||||||||||||
E-mail: ooco_ova@chmi.cz |