Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-06-10 08:42 CEST
Basic data | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | USNZA | ||||||||||||||||
Old ISKO number: | 1570 | ||||||||||||||||
Locality: | Sneznik | ||||||||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||||||||
Measuring networks: | AMS-SRS, National air pollution monitoring network | ||||||||||||||||
Administrator | |||||||||||||||||
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2 40011 Ústí n/Labem |
Tel.: 472 706 053 | ||||||||||||||||
E-mail: petr.goll@chmi.cz | |||||||||||||||||
Target of the measuring programme | |||||||||||||||||
Evalution of total level of concentrations beckground, Usage for operational management and regulation (SRVS) | |||||||||||||||||
Cover | |||||||||||||||||
container (air-conditioned) | |||||||||||||||||
Note | |||||||||||||||||
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||||||||
Measurements | |||||||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-05-20 | |
L1 | D1 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 10min | 2004-05-20 | |
L1 | D1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-05-20 | |
L1 | D1 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-05-20 | |
L1 | D1 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-05-20 | |
L1 | D1 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2004-05-20 | |
L1 | D1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-05-20 | |
L1 | D1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-05-20 | |
L1 | D1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-05-20 | |
L1 | D1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-05-20 | |
L1 | D1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2004-05-20 | |
L1 | D1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2004-05-20 | |
L1 | D1 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | Yes | No | 0 | Y | N | N | N | N | N | 1h | 2004-05-20 | 2009-07-15 |
L1 | D1 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | N | N | N | N | N | N | 1h | 2004-05-20 | 2009-12-31 |
L1 | D1 | RAIN [precipitation amount (rain am.)] | - | RAIN [standard rain gauge] | mm | No | No | 0 | N | N | N | N | N | N | 1h | 2004-05-20 | 2008-12-31 |
List of laboratories | |||||||||||||||||
Laboratory number 1 (L1) |
CHMI-Usti n/L AIM
pošt. přihrádka 2 400 11 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||||||||
E-mail: petr.goll@chmi.cz | |||||||||||||||||
List of data suppliers | |||||||||||||||||
Supplier number 1 (D1) |
ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2 40011 Ústí nad Labem |
Tel.: 472 706 053 | |||||||||||||||
E-mail: petr.goll@chmi.cz |