Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-11-28 03:43 CET


Basic data
Code: ALIBT
Old ISKO number: 1177
Locality: Praha 4-Libus
Type of measuring programme: Heavy metal in SPM
Measuring networks: EUROAIRNET
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Data for research, models, verification, etc.
Cover
measuring box (heated)
Note
Odběrové zařízení v kontejneru na travnaté ploše, odběrové zařízení pod deštníkem. Týdenní odběr. Od 1.1.1997 odběr. zařízení přesunuto do budky 10m od kontejneru, na travna ploše ve volné krajině (nová odběrová hlavice). Odběr : 24hod, analýza kovů každý 6.den, SPM denně. Od 19.2.2003 PM10 denně.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 0 SPM [suspended particulate matter] - GRV [gravimetry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 SPM [suspended particulate matter] - GRV [gravimetry] - No No 0 N N N N N N 1d 1997-01-01 2002-12-31
L1 D1 0 SPM [suspended particulate matter] - GRV [gravimetry] - No No 0 N N N N N N 1d/4d 2003-01-01 2003-03-15
L1 D1 0 Na [sodium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Mg [magnesium ] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Al [aluminium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Si [silicon] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 S [sulphur] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Cl [chlor] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 K [potassium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Ca [calcium ] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1994-01-01
L1 D1 0 Ca [calcium ] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Ti [titanium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 V [vanadium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Cr [chromium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Mn [manganese] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Mn [manganese] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Fe [iron] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1993-01-01
L1 D1 0 Fe [iron] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Ni [nickel] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Ni [nickel] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Cu [copper] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Cu [copper] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Zn [zinc] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Zn [zinc] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 As [arsenic] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1d/6d 2001-01-01 2002-12-31
L1 D1 0 As [arsenic] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Se [selenium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Br⁻ [bromide ions] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Rb [rubidium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Sr [strontium] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1d 1998-01-01 1998-04-30
L1 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1d/6d 1998-05-01 2002-12-31
L1 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1M 1985-01-01 1996-12-31
L1 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1d 1998-01-01 1998-04-30
L1 D1 0 Pb [lead] - XRF [X-ray fluorescence] - No No 0 N N N N N N 1d/6d 1997-01-01 2002-12-31
L1 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] - No No 0 N N N N N N 1d/6d 1998-05-01 2002-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 482
 