Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: AMLYA
Old ISKO number: 775
Locality: Praha 5-Mlynarka
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna na svahu asi 50m od frekventované komunikace. 30.11.2000 došlo k výměně prachoměru. Verewa F703V a sondy PM10 Kalman byly nahrazeny prachoměrem FH 62 I-R se sondami PM10 Anderson. 9.7.2003 - výměna sondy PM10 Anderson za sondu Digitel DPM10, u PM2,5 je so nda idigitel DPM2,5.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 Y N N N N N 1h 2004-01-01 2008-07-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 10min 2004-10-01 2008-07-31
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 19 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 19 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 19 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes No 0 Y N N N N N 1h 2004-01-01 2009-05-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes No 0 N N N N N N 30min 1993-06-30 2003-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No Yes 0 Y N N N N N 1h 2004-01-01 2010-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 2003-03-01 2003-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-03-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-10-19 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1992-02-01 1995-10-18
L1 D1 0 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 1992-02-01 1999-08-31
L1 D1 0 T [temperature (unspecificated)] - PT100 [resistance method] - No No 0 N N N N N N 30min 1996-01-01 1999-08-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 
E-mail: jan.silhavy@chmi.cz