Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-11-20 03:48 CET
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | ASROA | |||||||||||||||||
Old ISKO number: | 2140 | |||||||||||||||||
Locality: | Praha 10-Srobarova | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | ||||||||||||||||||
Administrator | ||||||||||||||||||
ZÚ se sídlem v Ústí n.Labem
Pasteurova 9 400 01 Ústí n/L |
Tel.: 724 034 029 | |||||||||||||||||
E-mail: pavel.knedlik@zuusti.cz | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evaluation of the effect on the population health | ||||||||||||||||||
Cover | ||||||||||||||||||
measuring box (heated) | ||||||||||||||||||
Note | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 61 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | Y | A | A | N | R | N | 1h | 2016-01-01 | |
L1 | D1 | 61 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | Y | A | A | N | R | N | 1h | 2016-01-01 | |
L1 | D1 | 61 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | - | Yes | Yes | 0 | Y | A | A | N | R | N | 1h | 2016-01-01 | |
L1 | D1 | 98 | PM 1 [fine particles PM1] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | Y | N | A | A | A | A | 1h | 2016-01-01 | |
L1 | D1 | 98 | PM₂.₅ [fine particles PM2.5] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | Y | N | A | A | A | A | 1h | 2016-01-01 | |
L1 | D1 | 98 | PM₁₀ [particles PM10] | - | OPEL [optoelectronic method] | - | Yes | Yes | 0 | Y | N | A | A | A | A | 1h | 2016-08-01 | |
L1 | D1 | 125 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
L1 | D1 | 125 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
L1 | D1 | 99 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
L1 | D1 | 99 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
L1 | D1 | 100 | GLRD [global radiation] | - | TDM [temperature difference method] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
L1 | D1 | 99 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | - | No | Yes | 0 | N | N | N | N | N | N | 1h | 2016-01-01 | |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
ZU se sidlem v Ustin.Labem
Pasteurova 9 400 01 Ústí n. Labem |
Tel.: 724 034 029 | ||||||||||||||||
E-mail: pavel.knedlik@zuusti.cz | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
ZU se sidlem v Usti n. L.
Pasteurova 9 400 01 Ústí n. Labem |
Tel.: 724 034 029 | ||||||||||||||||
E-mail: pavel.knedlik@zuusti.cz |