Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | BBNAA | |||||||||||||||||
Old ISKO number: | 2023 | |||||||||||||||||
Locality: | Brno-Masna | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | ||||||||||||||||||
Administrator | ||||||||||||||||||
ZU-Ostrava
Gorkého 6 602 00 Brno |
Tel.: 543 423 344 | |||||||||||||||||
E-mail: david.marek@zuova.cz | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evalution of concentration in urban areas | ||||||||||||||||||
Cover | ||||||||||||||||||
measuring box (heated) | ||||||||||||||||||
Note | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 0 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg∙m -3 | No | Yes | 0 | Y | N | A | A | N | A | 1h | 2015-01-01 | 2018-10-10 |
L1 | D1 | 0 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg∙m -3 | No | Yes | 0 | Y | N | A | A | N | A | 1h | 2015-01-01 | 2018-10-10 |
L1 | D1 | 0 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg∙m -3 | No | Yes | 0 | Y | N | A | A | N | A | 1h | 2015-01-01 | 2018-10-10 |
L1 | D1 | 88 | PM₂.₅ [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg∙m -3 | No | Yes | 0 | Y | N | A | A | N | A | 1h | 2015-01-01 | 2023-05-02 |
L1 | D1 | 88 | PM₁₀ [particles PM10] | - | OPEL [optoelectronic method] | µg∙m -3 | No | Yes | 0 | Y | N | A | A | N | A | 1h | 2015-01-01 | 2023-05-02 |
L1 | D1 | 35 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | Yes | 0 | N | N | N | N | N | N | 1h | 2015-01-01 | 2023-05-02 |
L1 | D1 | 35 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | Yes | 0 | N | N | N | N | N | N | 1h | 2015-01-01 | 2023-05-02 |
L1 | D1 | 60 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | N | N | N | N | N | N | 1h | 2015-02-05 | 2023-05-02 |
L1 | D1 | 60 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | N | N | N | N | N | N | 1h | 2015-01-01 | 2023-05-02 |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
KHS-Ostrava
Partyzánské náměstí 7 702 00 Ostrava 1 |
Tel.: 596 200 361 | ||||||||||||||||
E-mail: lucie.hellebrandova@zuova.cz | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
ZU-Ostrava
Grokého 6 602 00 Brno |
Tel.: 543 423 349 | ||||||||||||||||
E-mail: martina.svobodova@zuova.cz |