Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: BHODP
Old ISKO number: 2028
Locality: Hodonin
Type of measuring programme: Measuring program of PAHs
Measuring networks:
Administrator
ZU-Ostrava
Gorkého 6
602 00 Brno
Tel.: 543 423 344
 
E-mail: david.marek@zuova.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
measuring box (heated)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 140 BaA [benzo(a)anthracene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 Chry [chrysene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 BbF [benzo(b)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 BjF [benzo(j)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 BkF [benzo(k)fluoranthene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 B[𝑎]P [benzo[a]pyrene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 I123cdP [indeno(1,2,3,-cd) pyrene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 DBahA [dibenzo(a,h)anthracene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 BghiPRL [benzo(g,h,i) perylene] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
L1 D1 140 PAHs_TEQ [toxic equivalent of sum PAHs] HVSauto30 [HVS -automatic filter change 30 m3/h] HPLC [high pressure liquid chromatography] - Yes No 0 Y A A A N A 1d/3d 2015-01-01
List of laboratories
Laboratory number 1 (L1) Odd. Organickych analyz
Vrchlického 57
586 01 Jihlava
Tel.: 567 574 774
 
E-mail: jiri.fisar@zuova.cz
List of data suppliers
Supplier number 1 (D1) ZU-Ostrava
Grokého 6
602 00 Brno
Tel.: 543 423 349
 
E-mail: martina.svobodova@zuova.cz