Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: BZNOA
Old ISKO number: 1478
Locality: Znojmo
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
CHMI - pob.Brno
Kroftova 43
61667 Brno
Tel.: 541421046
 
E-mail: jachym.brzezina@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 25 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2010-01-07
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 2003-10-01 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 10min 2004-02-18 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 2003-10-01 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 2003-10-01 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 2003-10-01 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - Yes Yes 0 Y N N N N N 1h 2010-01-01 2012-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 2003-10-14 2003-12-31
L1 D1 35 WV [wind velocity] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2004-12-01 2012-12-31
L1 D1 35 WV [wind velocity] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 10min 2004-12-01 2012-12-31
L1 D1 35 WD [wind direction] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2004-12-01 2012-12-31
L1 D1 35 WD [wind direction] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 10min 2004-12-01 2012-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2006-01-01 2012-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 10min 2009-01-18 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2006-01-01 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 10min 2009-01-18 2012-12-31
L1 D1 41 h [relative air humidity (h. of air)] - HAIR [hair hygrometer] - No Yes 0 N N N N N N 1h 2004-12-01 2013-02-24
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] - No Yes 0 N N N N N N 1h 2005-01-01 2013-02-24
List of laboratories
Laboratory number 1 (L1) CHMI-pob.Brno-AMS
Kroftova 43
61667 Brno
Tel.: 541421044
 
E-mail: zuzana.vranova@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-Brno AIM
Kroftova 43
61667 Brno
Tel.: 541421046
 
E-mail: jachym.brzezina@chmi.cz