Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: CHVOA
Old ISKO number: 1103
Locality: Hojna Voda
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET, IRIS
Administrator
ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Kontejner umístěn na horské louce v sedle mezi Vysokou (1034m.n.m.) a Kuní horou (953m.n.m.) asi 300m od okraje obce Hojná Voda. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2015-05-12
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-01-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-01-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2007-01-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2007-01-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2007-01-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2007-01-01
L1 D1 97 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2004-01-01
L1 D1 97 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1994-03-11 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 N N N N N N 10min 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-03-11 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-03-11 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-03-11 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - Yes No 0 N N N N N N 30min 1994-09-01 2003-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 1h 2004-01-01 2004-09-30
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-10-24 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-03-11 1995-10-23
L1 D1 47 RAD_A [RAD_A] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-22
L1 D1 47 RAD_A [RAD_A] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-22
L1 D1 47 RAD_B [RAD_B] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-22
L1 D1 47 RAD_B [RAD_B] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-22
L1 D1 47 RAD_C [RAD_C] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-22
L1 D1 47 RAD_C [RAD_C] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-22
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1994-12-20 2002-11-27
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2002-11-28 2003-12-31
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1994-12-20 2002-11-27
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2002-11-28 2003-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 1h 2004-01-01 2009-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 1994-12-20 2003-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1994-12-20 2003-12-31
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No Yes 0 N N N N N N 1h 2004-01-01 2010-12-31
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No No 0 N N N N N N 30min 1998-06-01 2003-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No No 0 N N N N N N 30min 1994-12-20 2003-12-31
L1 D1 45 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1994-12-20 2003-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz