Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: CPRAA
Old ISKO number: 1225
Locality: Prachatice
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground, Usage for operational management and regulation (SRVS)
Cover
not defined
Note
Kontejner umístěn severovýchodně od středu města v nízké vilové zástavbě na vyvýšeném místě ve směru převažujícího proudění.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-05-01
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-05-01
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y A A A R A 1h 2005-05-01
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - No Yes 0 Y A A A R A 1h 2005-05-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2012-06-18
L1 D1 0 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N A N N N 1h 2016-07-26
L1 D1 0 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2016-07-26
L1 D1 0 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2016-07-26
L1 D1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2016-07-26
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-05
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No Yes 0 N N N N N N 10min 2004-06-03 2015-05-05
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-05
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - No No 0 N N N N N N 30min 1995-01-21 2005-04-30
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 1h 2005-05-01 2008-09-11
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-04
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 37 WV [wind velocity] - ELMAG [electromagnetic method] - No Yes 0 N N N N N N 10min 2005-05-02 2015-05-04
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-04
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 37 WD [wind direction] - OPEL [optoelectronic method] - No Yes 0 N N N N N N 10min 2005-05-02 2015-05-04
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 1h 2005-05-01 2009-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 45 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-04
L1 D1 45 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1995-01-19 2005-04-30
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No Yes 0 N N N N N N 1h 2005-05-01 2010-12-31
L1 D1 49 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No No 0 N N N N N N 30min 2001-01-01 2005-04-30
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No Yes 0 N N N N N N 1h 2005-05-01 2009-08-27
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No Yes 0 N N N N N N 10min 2005-05-01 2009-08-27
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-04
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
L1 D1 40 T10m [temperature 10m above terrain] - PT100 [resistance method] - No Yes 0 N N N N N N 1h 2005-05-01 2015-05-04
L1 D1 40 T10m [temperature 10m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1995-01-01 2005-04-30
List of laboratories
Laboratory number 1 (L1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz