Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-23 04:52 CEST


Basic data
Code: HKRYA
Old ISKO number: 1110
Locality: Krkonose-Rychory
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET, IRIS
Administrator
ČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
 
E-mail: jan.komarek@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna 20m od Rýchorské boudy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] - Yes Yes 0 Y A A A R A 1h 2004-01-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-11-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2004-11-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 36 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2007-01-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2007-01-01
L1 D1 36 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2007-01-01
L1 D1 97 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - Yes Yes 0 N N A N N N 10min 2004-12-01
L1 D1 97 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-01-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 N N N N N N 30min 1994-05-15 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 10min 2004-11-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-09 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-09 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-01-01 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 N N N N N N 30min 1994-02-09 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] - Yes No 0 N N N N N N 30min 1996-01-01 2003-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 Y N N N N N 1h 2004-01-01 2006-12-31
L1 D1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 N N N N N N 30min 1995-12-15 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-03-31 1995-12-14
L1 D1 119 RAD_A [RAD_A] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-26
L1 D1 119 RAD_A [RAD_A] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-26
L1 D1 119 RAD_B [RAD_B] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-26
L1 D1 119 RAD_B [RAD_B] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-26
L1 D1 119 RAD_C [RAD_C] - RAD [dosimeter] - No Yes 0 N N N N N N 1h 2004-01-01 2017-03-26
L1 D1 119 RAD_C [RAD_C] - RAD [dosimeter] - No Yes 0 N N N N N N 10min 2004-01-01 2017-03-26
L1 D1 36 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-06-15 2000-11-20
L1 D1 36 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2000-11-21 2003-12-31
L1 D1 36 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-06-15 2000-11-20
L1 D1 36 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2000-11-21 2003-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 1995-03-01 1996-03-31
L1 D1 40 T [temperature (unspecificated)] - PT100 [resistance method] - No No 0 N N N N N N 30min 1998-01-01 1998-12-31
L1 D1 45 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No No 0 N N N N N N 30min 1997-10-01 2003-12-31
L1 D1 37 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No Yes 0 N N N N N N 1h 2004-01-01 2015-05-15
L1 D1 48 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] - No No 0 N N N N N N 30min 1999-01-01 2003-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No No 0 N N N N N N 30min 1995-03-01 2003-12-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1999-01-01 2003-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 042
 
E-mail: jan.komarek@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 042
 
E-mail: jan.komarek@chmi.cz